Flashing Light (option)
Figure 7.19 - Flashing Light
Vi sually check the op tional flash ing light, to see
that the light flashes at ap prox i mately one flash per
sec ond when the mo tor key switch is turned on.
■
Ground Control Switches
Figure 7.20 - Ground Control Switches
With the Ground/Platform Selector
set to
ground:
Check that each of the platform moving switches
(
through to
) cause the MHP15J to move the
way it should.
Check both po si tions of each switch.
For cor rect op er at ing pro ce dures see the “Op er a -
tion” chap ter 8.
NOTE
Pay particular attention to the
Emergency Stop
switch
to see that it turns the MHP15J engine
off when the red cover is struck.
■
Emergency Lower
❑
Lower control box
Figure 7.21 - Emergency Lower Valve
With the booms raised open the
Emergency
Lower Valve
on the top of the manifold valve.
The booms should be gin to lower. The rate of low -
er ing can be reg u lated by the amount the valve is
opened.
To check the slew func tion when us ing the man ual
emer gency lower valve the
Mas ter Key Switch
and
Emer gency Stop
switch must be on and the
Plat form/ground Se lec tor
must be set to ground.
To slew (with the man ual emer gency lower valve
al ready open) se lect the re quired di rec tion on the
slew tog gle switch .
NOTE
The manual emergency lower valve must be
closed after the test to ensure proper boom
operation.
For cor rect emer gency low er ing op er at ing pro ce -
dures see “Emer gency Op er a tion” chap ter 9.
❑
Upper control box
Emer gency lower from the up per con trol box is
achieved by turn ing the up per con trol to on and de -
press ing the foot switch whilst op er at ing the
Emer -
gency Lower
switch
To slew the unit se lect the di rec tion re quired on the
slew tog gle switch at the same time. For cor rect
emer gency low er ing op er at ing pro ce dures see
“Emer gency Op er a tion” chap ter 9.
page 7 - 6
MHP15J – 11995A
7. Pre-operational Inspection
Summary of Contents for MHP 15J
Page 1: ...Engine Powered Gasoline Battery Electric Operator s Manual P N 11995A September 2005 V2...
Page 16: ...page 1 8 MHP15J 11995A 1 Safety...
Page 20: ...page 2 4 MHP15J 11995A 2 Safety Devices...
Page 26: ...page 3 6 MHP15J 11995A 3 Specifications...
Page 28: ...page 4 2 MHP15J 11995A 4 Gauges...
Page 30: ...page 5 2 MHP15J 11995A 5 Shut offs and Circuit Breakers...
Page 36: ...page 6 6 MHP15J 11995A 6 Controls...
Page 46: ......
Page 54: ...page 8 8 MHP15J 11995A 8 Operation...
Page 60: ...page 11 2 MHP15J 11995A 11 Options...
Page 66: ...page 13 2 MHP15J 11995A 13 Operator s Troubleshooting...
Page 70: ......