background image

snellgroup.com

User Instruction Manual

IQSDA30/IQSDA32

Intelligent Reclocking High Performance HD-SDI/SD-SDI Distribution 
Amplifiers

Summary of Contents for IQSDA30

Page 1: ...snellgroup com User Instruction Manual IQSDA30 IQSDA32 Intelligent Reclocking High Performance HD SDI SD SDI Distribution Amplifiers...

Page 2: ...l Limited or their authorized agents Reproduction or disassembly of embedded computer programs or algorithms prohibited No part of this publication can be transmitted or reproduced in any form or by a...

Page 3: ...Specification 10 2 1 IQSDA30 10 2 2 IQSDA32 12 3 Connections 14 3 1 IQSDA30 14 3 1 1 Inputs 14 3 1 2 Outputs 14 3 2 IQSDA32 15 3 2 1 Inputs 15 3 2 2 Outputs 15 4 Card Edge LEDs 16 5 Controlling the IQ...

Page 4: ...4 2015 Snell Limited 5 6 Setup 25 5 6 1 Product Information 25 5 6 2 Default Settings 25 5 6 3 Factory Defaults 25 5 6 4 Restart 26 5 6 5 Input 1 2 Name 26 6 Controlling the IQSDA30 32 from an Active...

Page 5: ...tion applications For HD SD only applications an HD SD SDI version is available with an option to upgrade firmware for 3 Gbit s operation when required 1 1 2 IQSDA32 The IQSDA32 is a distribution ampl...

Page 6: ...fier 2 inputs 3 outputs per input IQSDA3061 1A3 IQSDA3061 1B3 Dual Channel 3G HD SD SDI Re clocking Distribution Amplifier with relay input bypass 2 inputs 2 outputs per input IQSDA30 3G Upgrade for I...

Page 7: ...B IQSDA3047 1A B 3 IQSDA3061 1A B 3 1 3 2 IQSDA32 IQSDA3247 1A B IQSDA3247 1A B 3 IQSDA3261 1A B IQSDA3261 1A B 3 Note The input signal will bypass the module and be routed to the respective output i...

Page 8: ...yle Enclosures Enclosure order code IQH1A S P Enclosure order codes IQH3A S 0 IQH3A S P Enclosure order codes IQH3A E 0 IQH3A E P IQH3A 0 0 IQH3A 0 P Enclosure order code IQH1A S P Important Although...

Page 9: ...SMPTE424M HD SDI to SMPTE292M SD SDI to SMPTE259M C DVB ASI Relay Bypass option available RollCall monitoring allows all signal paths to be managed Extremely compact up to 32 channels in 3RU for use...

Page 10: ...K Green flashing Input 1 OK Green Bypass Orange Loss Red Input 2 OK Green Bypass Orange Loss Red RollCall Features Input 1 2 Rate Select Auto 3G HD SD DVB ASI Bypass reclocking off Input Status Presen...

Page 11: ...Mbit s SDI SMPTE 259M C DVB ASI Connector Format BNC 75 Ohm panel jack on standard Snell connector panel Return Loss 15 dB 270 Mbit s 1 5 Gbit s 10 dB 3 Gbit s Output Jitter SD SDI 0 2 UI 10 Hz 0 2 U...

Page 12: ...compatible Controls Indicators Power OK Green CPU OK Green flashing Input OK Green Bypass Orange Loss Red RollCall Features Input 1 2 Rate Select Auto 3G HD SD DVB ASI Input Status Present Loss Unkno...

Page 13: ...SDI SMPTE 292M 270 Mbit s SDI SMPTE 259M C DVB ASI Connector Format BNC 75 Ohm panel jack on standard Snell connector panel Return Loss 15 dB 270 Mbit s 1 5 Gbit s 10 dB 3 Gbit s Output Jitter SD SDI...

Page 14: ...l input to the unit is made via 2 BNC connectors which terminate in 75 Ohms IQSDA3047 1A B IQSDA3047 1A B 3 IQSDA3061 1A B 3 3 1 2 Outputs Serial digital output from the unit is made via 6 BNC connect...

Page 15: ...onnector which terminate in 75 Ohms IQSDA3247 1A B IQSDA3247 1A B 3 IQSDA3261 1A B IQSDA3261 1A B 3 3 2 2 Outputs Serial digital output from the unit is made via 7 BNC connectors 6 on Relay Bypass ver...

Page 16: ...r is illuminated when there is unknown or no input on input channel 1 Channel 1 Rate Green This indicator pair shows the rate on input channel 1 as follows Both LEDs illuminated 3 Gbit s Left LED only...

Page 17: ...m the RollCall Control Panel 5 1 Unit Status Information about the status of the unit is displayed in the Unit Status section on each RollCall Control Panel screen The first two lines of the Unit Stat...

Page 18: ...ls are greyed out and are inactive If any other standard is applied to the unit the output will be muted HD 1 5 Gb When selected the unit will reclock only HD 1 5 Gb signals When selected the On Input...

Page 19: ...ption applies a mute on Output 1 On Input loss Mute When selected if the Input signal is lost the output signal will be muted On Input loss Pass When selected if the input signal is lost it will be pa...

Page 20: ...in the Recall Memory column To change a memory name In the Save Memory Name field type the new memory name and then click S To return the memory to its default value click the preset button P Use the...

Page 21: ...about several parameters can be made available to a logging device that is connected to the RollCall network Each logging screen comprises three columns Log Enable Select the check boxes that corresp...

Page 22: ...RE_VERSION Displays the hardware version number UPTIME Displays the time since the last restart in the format ddd hh mm ss LICENSED_OPTIONS Displays the licensed features installed in the module INPUT...

Page 23: ...o be set up Dragging the slider selects the RollTrack Index number Clicking the P button selects the default preset value 5 5 3 RollTrack Source This slider enables the source of information that trig...

Page 24: ...t to the selected destination unit The command may be changed by typing a code in the text area and then selecting the S button to save the selection Clicking the P button returns to the default prese...

Page 25: ...re Version The currently installed software version number Serial No The module serial number Build The factory build number This number identifies all parameters of the module KOS The operating syste...

Page 26: ...nell Limited 5 6 4 Restart The Restart button enables the module to be rebooted simulating a power up power down cycle 5 6 5 Input 1 2 Name These are the input names displayed in logging To change the...

Page 27: ...of text indicating the current state of the unit 6 2 Control Window The Control window displays all selection menus and sub menus The main or top level menu allows various sub menus to be selected by...

Reviews: