5.6 RollTrack

The RollTrack screen allows information to be sent, via the RollCall™ network, to other 
compatible units connected on the same network.

5.6.1 Disable All

When checked, all RollTrack items are disabled.

5.6.2 Index

This slider enables up to 16 RollTrack outputs to be setup. Dragging the slider selects the 
RollTrack Index number, displayed below the slider. Clicking the 

P

 button selects the default 

preset value.

5.6.3 Source

This slider enables the source of information that triggers the transmission of data to be 
selected. Dragging the slider selects the RollTrack source, displayed below the slider. 
Clicking the 

P

 button selects the default preset value. When no source is selected, 

Unused

 is 

displayed.

Unused

No RollTracks sent.

Input N OK

Valid serial data input received.

Input N None

No serial data input received.

Input N Bitrate 270

Received bitrate is 270 Mbit/s.

Input Bitrate 1.5

Received bitrate is 1.5 Gbit/s.

Input N Bitrate 3G

Received bitrate is 3 Gbit/s.

Input N Bitrate Un.

Received bitrate is unknown.

TX N Bias OK

LASER Bias current within limits.

TX N Bias High

LASER Bias current above limits.

TX N Bias Low

LASER Bias current below limits.

RX N Power OK

Receive power is within limits.

RX N Power High

Receive power is above limits.

RX N Power Low

Receive power is below limits.

Summary of Contents for IQFDA30

Page 1: ...snellgroup com User Instruction Manual IQFDA30 3G HD SD SDI Re clocking Distribution Amplifier with Fiber I O...

Page 2: ...rates a policy of continuous improvement and development Snell reserves the right to make changes and improvements to any of the products described in this document without prior notice Contact Detail...

Page 3: ...1 1 Unit Status 12 5 1 2 SFP Status 12 5 2 Input 13 5 2 1 Input 13 5 2 2 Outputs 13 5 3 SFP 14 5 3 1 SFP Transmit 14 5 3 2 SFP Receive 14 5 4 Memory 1 16 15 5 4 1 Recall Memory 15 5 4 2 Save Memory 15...

Page 4: ...QFDA30 provides HD SDI 3 Gbit s 1 5 Gbit s or 270 Mbit s SD SDI inputs with both SDI and Fiber optic outputs in a single width package Its 80m 3G 170m HD and 300m SD input equalization performance and...

Page 5: ...signal paths to be managed 1 4 Order Codes The following product order codes are covered by this manual The following SFP modules are available for this product 1 5 Rear Panel View The following rear...

Page 6: ...3A S 0 IQH3A S P Enclosure order codes IQH3A E 0 IQH3A E P IQH3A 0 0 IQH3A 0 P Enclosure order code IQH1A S P Important Although IQ modules are interchangeable between enclosures their rear panels are...

Page 7: ...s Fiber Signal Input SDI Inputs 1 Optical 3 Gbit s HD SDI 1 485 Gbit s HD SDI 270 Mbit s SD SDI Connector Format LC singlemode Conforms to SMPTE 297 2006 SMPTE 424M HD level A B SMPTE 292M HD SMPTE 2...

Page 8: ...ngth Input 1 Rx Power High Warning Input 1 Rx Power Low Warning Input 1 Rx Power Measurement RollTrack Index Up to 16 RollTrack destinations RollTrack Controls On Off Index Source Address Command Stat...

Page 9: ...0 to 5 dBm 2 dBm typical Rise and Fall Time 135 ps 3 Gbit s 270 ps 1 5 Gbit s 1 5 ns 270 Mbit s Extinction Ratio 7 5 1 typical Optical Return Loss 27 dB Link Distance Up to 30 Km 3 Gbit s Up to 21 Km...

Page 10: ...input and output connections provided by the IQFDA30 3 1 SDI Input 3 2 SDI Outputs 3 3 SFP Serial digital input is made to the unit via a BNC connector which terminates in 75 Ohms Serial digital outpu...

Page 11: ...esent RUN MON Green Flashing The CPU is running OK Green Illuminated Input channel 1 is locked to the input signal WARN Yellow Illuminated The signal on input channel 1 is not being re clocked That is...

Page 12: ...ol panel will change to reflect the current product configuration The screens shown in this section are for guidance and reference only and may be slightly different to those on your module Name Descr...

Page 13: ...ted the unit will re clock 3G 3 Gb signals Others When selected signals that are not of any of the above rates will be re clocked Reclock Bypass When selected the unit will not re clock the input sign...

Page 14: ...FAIL LO and FAIL HI Tx Power Displays the signal level of the transmitted output signal in dBm Tx Wavelength Displays the wavelength of the transmitted output signal either 1310 nm or 1550 nm Laser B...

Page 15: ...Memory section 5 4 2 Save Memory This column lists the 16 pre set memory names that are available for use To save settings In the Save Memory column select a memory location and then click Save The cu...

Page 16: ...d 5 4 4 Save Memory Name This option enables the pre set memory names to be changed to something more memorable or meaningful if required To change a memory name In the Save Memory Name field type the...

Page 17: ...mprises three columns Log Enable Select the check boxes that correspond to the parameters for which log information should be collected Log Field Displays the name of the logging field Log Value Displ...

Page 18: ...ellgroup com Operation Using the RollCall Control Panel Issue 1 Rev 2 Page 18 2013 Snell Limited 5 5 3 Logging SFP The Logging SFP screen is used to select which fields should be enabled for each of t...

Page 19: ...The last recalled memory POWER USAGE The power rating for the module Note this is not a live power reading INPUT_1_IDENT The identifier of the serial data input INPUT_1_NAME The name of the serial da...

Page 20: ...Rev 2 Page 20 2013 Snell Limited OUTPUT_N_LASER_BIAS_STATE Displays the laser bias status Valid values are OK WARN HI WARN LO FAIL LO FAIL HI Log Field Description Note N should be replaced with the...

Page 21: ...the transmission of data to be selected Dragging the slider selects the RollTrack source displayed below the slider Clicking the P button selects the default preset value When no source is selected U...

Page 22: ...electing the S button to save the selection Clicking the P button returns to the default preset command The RollTrack command consists of two sets of numbers for example 84 156 The first number 84 is...

Page 23: ...n number PCB The Printed Circuit Board revision number Rear Type The rear panel type Licensed Options The installed licensed options 5 7 1 Default Settings The Default Settings button enables module s...

Page 24: ...es the module to be rebooted simulating a power down power up cycle 5 8 2 Configure Type In the event of the module not recognizing the SFP the Configure Type controls will become available for manual...

Reviews: