7.2.4 Setting Up the RollCall Settings
In the
RollCall Settings
section of the System-Setup template (see Figure 58):
10. Enter the following RollCall settings:
(Enter settings and press
S
to save each change locally.)
7.2.5 Assigning Network Interfaces as Fabric A or B
In the
IP Fabric
section of the System-Setup template (see Figure 59):
11. Select a network interface to assign it to be Fabric “A” or “B” connection(s) to the
internal MV-805 IP multiviewer function.
This is done via a drop-down menu. Make the following assignments:
Figure 58 RollCall Settings Box
•
RollCall Network:
RollCall network address.
•
RollCall Unit:
RollCall unit number.
(Must be unique for each RollCall device on the RollCall
network.)
•
Domain ID:
R Domain ID number for multiviewer control
messages.
(The same Domain ID should be used when connecting
SAM Orbit for Multiviewers to the unit.)
•
Ethernet
Interface:
Select the MV-805’s control network interface.
Note:
Multiviewer Control Messages Domain ID in “RollCall Settings”:
The R Domain ID used here is for multiviewer control messages.
This should be the same as that used for:
•
SAM Orbit connecting to the MV-805 unit with a Multiviewer SAM Orbit project.
Figure 59 IP Fabric Section of System-Setup Template
•
Interface 1 Fabric A
Select ‘
ens2f0
’
•
Interface 1 Fabric B
Select ‘
ens2f1
’
•
Interface 2 Fabric A
Select ‘
ens1f0
’ (MV-805-32 only)
•
Interface 2 Fabric B
Select ‘
ens1f1
’ (MV-805-32 only)