5.2 Video 1 / 2
The
Video 1 / 2
screens enable you to specify the settings for the serial data input for
processing channels 1 and 2:
•
Valid Input standards.
•
The default output standard.
•
Any required ancillary blanking.
•
Freeze options and apply a manual freeze to the output image.
•
The default output.Video delay settings
The settings on the
Video 1
and
Video 2
pages are identical.
5.2.1 Valid Input Standards
The
Valid Input Standards
check boxes specify the video input standards that the module will
accept. The module will automatically detect the standard of the received input and block any
signal that does not comply with these selected video formats.
By default, all input standards are selected.
5.2.2 Default Output
The
Default Output
control specifies the module’s output in the event of signal loss at the
input. Options are:
•
Black:
video out is a black screen
•
Freeze:
video output is frozen/paused
•
Pattern:
video output is a pre-determined test pattern or information screenDefault
Output Standard