background image

Short press         key to change the reference point. 

The device reference point by default is rear.

Back Light On/Off

Changing Reference Point

Long press button        , reset current measurement 

unit, the default unit is: 0.000m. There are 6 units for 

selection.

Unit Setting

The back light is set to turn on and off automatically. 

The back light can be on for 15s while operating, and 

it will be shut off automatically in 15s when there is no 

operation to the device.

Keys sound

When the rangefinder is turned on, the buzzer sound 

will be turned on by default and cannot be muted.

Units:

Length

Area

Volume

1

6

5

4

3

2

0.000m

0.00 ft

0'00" 1/16

0  1/16 in

0.0 in

0.00m

0.000 m

2

0.00 ft

2

0.00 ft

2

0.00 ft

2

0.00 ft

2

0.00 m

2

0.000 m

3

0.00 ft

3

0.00 ft

3

0.00 ft

3

0.00 ft

3

0.00 m

3

- 4 -

Summary of Contents for SW-G10S

Page 1: ...SW G4S SW G6S SW G8S SW G10S Laser Distance Meter User s Manual...

Page 2: ......

Page 3: ...out of reach of children and avoid using by any irrelevant personnel It is strictly prohibited to shoot eyes or other parts of body with the laser It is not allowed take the laser to shoot any object...

Page 4: ...n Measuring Area Volume Pythagorean Mode Turn off Remove Reference Point Unit Switch Addition Subtration Save Power Supply Area Volume and Pythagorean Laser on Maximum Auxiliary Display Record Minimum...

Page 5: ...t Under on status long press button for 3 seconds to turn the device off The device can also be shut off without any operation for 150 seconds Discharge the battery door on the back of device and plac...

Page 6: ...et to turn on and off automatically The back light can be on for 15s while operating and it will be shut off automatically in 15s when there is no operation to the device Keys sound When the rangefind...

Page 7: ...y short press of the button under measuring mode press the button again for single measurement of length then the measured results displayed in the major display area Self Calibration This function ca...

Page 8: ...ion for volume measuring Press for length Press again for width Press thirdly for height The resent measuring result of length is showed in the auxiliary display area Press clear off the result and me...

Page 9: ...three times to enter Pythagoras mode the hypotenuse of blinking Press measure the length of hypotenuse a Press measure the length of one leg b Device the length of another leg x 1 Calculate the secon...

Page 10: ...f another side c Device calculates the length of the leg in full line x 3 Press five times till the one side of blinking on the screen Legs must short than hypotenuse or there will be err shows on scr...

Page 11: ...be showed on the screen Area cumulative function Measure the first area as showing in PIC1 Then press button and measure the second area as showing in PIC2 there is a in the left bottom At last press...

Page 12: ...r4 Err5 Info message Cause Solution Signal is too weak Out of distance measurement range Use the device within the range Chose the surface with stronger reflectance Use the reflecting plate Signal is...

Page 13: ...Area and Volume measurement function Pythagorean proposition measurement function Add and subtract measurement function Area measurement function Min Max value Self Calibration Laser level Laser type...

Page 14: ...rosion liquid is never allowed to use for the meter maintenance Laser output window and its focus lens can be maintained according to maintenance procedures for optical device Please check if the acce...

Page 15: ......

Page 16: ...Hongkong Sndway Instrument Company Limited Url www sndway com E mail market sndway com...

Reviews: