Scanner
Viewing and Saving Data (PIDs)
49
Figure 6-42
Trigger set (not armed)
z
Arming triggers:
1.
Select the
Trigger
icon.
2.
Select
Arm Triggers
.
The trigger point lines change color to indicate an armed condition
(
).
All set PID triggers are armed simultaneously (if more that one is set). Once armed it
remains armed until you clear it or the trigger is activated.
Figure 6-43
Trigger armed
About Activated Triggers
A trigger is activated (displays red flag)
when a PID value meets an upper/lower
limit (trigger point).
When a trigger is activated:
•
Data collection is briefly paused as the Scanner captures a recording of all
available PID data, and saves it as a data file.
•
A gray cursor line is displayed to indicate the point at which the data was
paused or saved.
•
An audible alarm is sounded
•
A message displays indicating a data file was saved.
•
Data collection continues.
•
The activated PID trigger is disarmed.
Note
- if a different PID trigger is
activated subsequently, an additional data file will be recorded.
•
A red cursor line is displayed on the graph of the PID with the activated trigger
to indicate where the trigger occurred. A green cursor line is displayed on all the
other PID graphs to indicate their relationship to where the trigger occurred.
Figure 6-44
Trigger activated