• 27 •
Disconnect HP coupling. Start A/C system with LP coupling
connected, press ENTER.
The A/C system will recover the refrigerant into the service hoses,
then the following screen will be displayed:
Disconnect LP coupling, then press ENTER to continue:
The machine will recover the residual refrigerant into the service
hoses, then the following screen will be displayed
:
Procedure is now successfully completed.
Press PRINTER to print the receipt of the procedure. Press ENTER
to exit...
SERVICES
The machine keeps track of the operations done on refrigerant
fluid: recovery, system refilling, inner bottle filling. For any
operation, a record is made with date, time, type of operation,
quantities involved, plate number, inner bottle refrigerant fluid
availability. From the MAIN MENU:
Select the MANUAL PROCEDURE, the following screen will be
displayed:
R134a
mm/dd/yyyy
hh:mm
xxxxxxx
AUTOMATIC MANUAL SERVICES
SETUP MAINTENANCE INFO
R134a
MANUAL PROCEDURE
xx
psi
EMPTY HOSES
Empty hoses
Hoses pressure
R134a
MANUAL PROCEDURE
CHARGE
Disconnect LP coupling, from A/C system and
Press ENTER
R134a
MANUAL PROCEDURE
EMPTY HOSES
End Of Procedure