18
EEWB332B
4.4 SELECTING OPERATOR PREFERENCES
4.4.1 FINE BALANCING MODE
This balancer measures with the maximum precision
availa ble all the time, 1g / 0.05 oz, however values
below 5g / 0.25 oz are shown as zero while in the
normal operating mode. Values exceeding 5g / 0.25 oz
are rounded to the amount of the nearest commercial
wheel weight.
Press the
FINE
button to advance to the display
resolution between 5g / 0.25 oz and 1g / 0.05 oz.
4.4.2 OUNCE/GRAMS CONVERSION
When the machine is fi rst turned on it is preset to display
the imbalance in ounces.
Press the
MODE
button to advance to select ounces
or grams.
Select Enter to save selection.
4.4.3 RIM DIAMETER IN MILLIMETERS
The rim diameter is normally displayed in inches,
however if the value in millimeters is desired. Press
the MODE button until “PAX/mm” is NOT illuminated
to display in inches, when lit the unit displays in mm.
4.5 ENTER RIM PARAMETERS
4.5.1 Rim Distance and Diameter (offset)
- Move
the rim offset arm to the edge of the rim, touch the
pointer to the rim edge as illustrated in Figure 23a
and hold steady for about a second. The beeper
will sound when the distance and diameter values
are calculated and entered. Return the arm to its
fully in and down position on the balancer. Do not
allow the measurement arm to “dangle” down in
front of the balance.
.
Figure 23a
4.5.2 - Rim Width Measurement -
Lower the hood
guard. The rim width will be automatically enter
using the sonar sonic device mounted on the hood
guard frame.
4.5.3. Measure/Enter rim width (manual)
using
rim width calipers. Measure wheel where correc-
tive clip-on weight would be applied, Figure 23b.
Press the Width entry key, Figure 23a, and enter
the measured width by pr/- keys until the
desired value appears in the display.
Figure 23b
W
Figure 23