9
EEWB330B
2.2 ELECTRIC INSTALLATION
ANY ELECTRICAL WIRING MUST BE PER-
FORMED BY LICENSED PERSONNEL.
ALL SERVICE MUST BE PERFORMED BY AN
AUTHORIZED SERVICE TECHNICIAN.
Check on the plate of the machine that the electrical
specifi ca tions of the power source are the same as
the machine. The machine uses 115VAC, 60Hz, 1Ph,
4.0 Ampere.
NOTE:
Any electrical outlet installation must be
verifi ed
by a licensed electrician before connecting the
balancer.
NOTE:
This machine performs a self-test routine on start-
up. There will be a delay of several seconds before
the display is activated.
2.0 BALANCER INSTALLATION
Mounting the Shaft Adapter
IMPORTANT!
CHECK THAT THE SURFACES ARE PERFECTLY
CLEAN AND NOT DAMAGED. AN INCORRECT
MOUNTING MAY RESULT IN SIGNIFICANT IMBAL-
ANCE.
A.
Mount the threaded shaft onto the arbor of the
balancer. Tighten fi rmly using supplied rod. (Figure 6).
Figure 6
B.
Install the accessory pins (Figure 7). Tighten fi rmly.
Figure 7
C.
Place cones and other accessories onto the acces-
sory pins.
Summary of Contents for EEWB330B
Page 1: ...EEWB330B DIGITAL WHEEL BALANCER OPERATOR S MANUAL MANUEL OPÉRATEUR MANUAL DE OPERADOR ...
Page 2: ......
Page 38: ...38 EEWB330B NOTES ...
Page 74: ...74 EEWB330B REMARQUES ...
Page 110: ...110 EEWB330B NOTAS ...
Page 111: ...111 EEWB330B NOTES ...