background image

4. With work piece contact against the work piece, pull trigger. The trigger must

operate smoothly.

5. Connect air supply and set regulator for 70 psi. DO NOT load a fastener strip.

6. Select Single Sequential Actuation Operation. Check for leaks. Without pulling

the trigger, press the work piece contact against the work piece. The tool MUST
NOT 
operate. Holding the tool away from the work piece, pull trigger and hold
for 5 seconds. The tool MUST NOT operate. Repeat steps several times.
Without pulling trigger, press nailer against work piece and pull trigger. The tool
MUST operate. Release trigger. Driver MUST move up.

7. Select Contact Actuation Operation. Holding nailer away from work piece, pull

trigger. The tool MUST NOT operate. While still pulling trigger, press the nailer
against work piece. The tool MUST operate.

8. If Steps 1 through 7 function properly, prepare the tool for use. Select opera-

tion mode and load fasteners. 

9. Set the required depth of drive. 

10. Repeat these steps daily. Test again if the nailer is dropped, jammed, etc.

USING THE AIR NAILER

To drive a nail, place the work piece
contact of the air nailer against the work
piece and pull the trigger. See Figure 6.

To avoid any unexpected nailings, 
perform the operation as follows:

1. Avoid placing the work piece contact

against the work piece with excessive
force.

2. Pull the trigger fully and hold it in the

fired position for 1 to 2 seconds
before releasing the trigger. This will
give the air nailer time to completely
expend the previous nail and build
enough pressure for the next nail.

14

In order to prevent the surface of the work piece from being scratched or damaged,
use the nose adapter. Install nose adapter by fitting the protrusion on the inside of
adapter with notch in contact arm. See Figure 5. 

Store the nose adapter in place when not being used.  

Never use a non-relieving air coupler with the angled

finish nailer. Always use couplers that release any built-up charge in the
angled finish nailer’s firing mechanism. A non-relieving air coupler can
allow the angled finish nailer to discharge a fastener while the tool is dis-
connected from the power source. Failure to comply with this warning can
result in serious or permanent injury or even death to the operator or to
bystanders.

When the air hose is disconnected, the pressure reservoir in the air nailer will dis-
charge removing any built-up air inside the tool.

REQUIRED DAILY PREPARATION

The following steps should be performed on a daily basis to ensure the angled fin-
ish nailer is operating correctly:

1. Disconnect air supply from nailer and remove fastener strip.

2. Check all screws, nuts and pins and ensure all are tight.

3. Press the pusher release button and slide back the pusher assembly

(Overriding the reload indicator). Press the work piece contact against a work
piece ensuring smooth movement.

13

Figure 6

Figure 5

Summary of Contents for 870013

Page 1: ...NAILER INSTRUCTION MANUAL THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY OPERATION MAINTENANCE AND STORAGE OF THIS PRODUCT BEFORE USE READ CAREFULLY AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS FAILURE TO DO SO COULD RESULT IN SERIOUS PERSONAL INJURY AND OR PROPERTY DAMAGE IF YOU SHOULD HAVE ANY QUESTIONS OR EXPERIENCE A PROBLEM WITH YOUR SNAP ON PRODUCT DO NOT...

Page 2: ... alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicates ...

Page 3: ...ed finish nailer is being used Distractions can result in severe injury or even death to anyone who inadvertently gets in the way of nailing operations Do not use oxygen combustible or bottled gases such as carbon dioxide or nitrogen as a power source for the angled finish nail er Use only compressed air from a source as outlined in this man ual The tool will explode resulting in severe injury or ...

Page 4: ... work area should be clear and free of litter Do not connect angled finish nailer to an air source capable of generating more than 200 psi 14 06 kg cm2 G Over pressurizing the angled finish nailer will result in bursting abnormal operation or breakage of the tool Use only clean dry regulated compressed air at levels specified on the tool Failure to comply can cause severe injury or death to the op...

Page 5: ...n inside diameter of 1 4 6 5 mm or greater and a hose length of less than 6 6 ft 20 m it is recommended that a 0 5 second interval be allowed between each nailing Air supply hoses shall have a minimum working pres sure of 150 psi 10 7 kg cm2 G or 150 of the maximum pressure produced by the compressor or whichever is higher Low air output by the compressor or a longer hose with a smaller inside dia...

Page 6: ...und to the connector threads before insertion 3 Snap the air hose onto the quick disconnect on the air nailer Check for air leaks LUBRICATION To ensure maximum performance it is recommended to install an air set oiler reg ulator and air filter as close as possible to the air nailer Adjust the oiler so that approximately one drop of oil will be released for every 50 nails If an air set is not used ...

Page 7: ... ment knob is already set to its lowest setting decrease the air pressure Should nails be driv en too deep even when the adjustment knob is set at its lowest setting decrease the air pres sure In general the angled finish nailer will have a longer service life when the adjustment knob is set a lower setting causing less wear and tear on the driving mechanism Always disconnect the air nailer before...

Page 8: ...ll the trigger fully and hold it in the fired position for 1 to 2 seconds before releasing the trigger This will give the air nailer time to completely expend the previous nail and build enough pressure for the next nail 14 In order to prevent the surface of the work piece from being scratched or damaged use the nose adapter Install nose adapter by fitting the protrusion on the inside of adapter w...

Page 9: ... be secured in a locked location to prevent unauthorized usage Avoid exposure to direct sunlight and or locations with high humidity and heat DO NOT hold the trigger in a half pulled position This could cause an unexpected nailing to occur if the work piece contact is permit ted to re contact the work piece Failure to comply could result in damage to work piece CHANGING DIRECTION OF EXHAUST AIR Th...

Page 10: ...every use using pneumatic tool oil Extends life of angled finish nailer Apply 2 3 drops of pneumatic tool oil to angled finish nailer air inlet after every use Nailer operates but no nail is driven Check for jammed nail Ribbon spring weakened or damaged Inspect nail feeder mechanism Ensure correct nails are being used Clear jammed nail Replace ribbon spring Clean and lubricate nail feeder Use ONLY...

Page 11: ... 2731 Spring 8 A0308 0101 Disc Valve 9 A0200 0051 O Ring 13 8 2 4 10 A0200 0531 O Ring 48 2 5 11 A0311 0581 Seal Air 12 A0103 0221 Ring 13 A0200 0131 O Ring 35 3 5 PROBLEM POSSIBLE CAUSE SOLUTION PARTS DIAGRAM 19 Drives nails properly during normal nailing operations but fails to drive nails fully at faster operating speeds Check inside diameter of air hose Switch to air hose with larger inside di...

Page 12: ...mper 34 A0401 2071 Body 35 A0004 0021 Nylon Nut M5 36 A0205 0611 Gasket 37 A0316 0321 Hook 38 A0203 0191 Filter 39 A0306 1161 Tail Cover 40 A0011 0161 Spring Pin 3 24 41 K0500 1511 Trigger Set 42 A0005 0311 Pin Retainer 5 5 2 43 A0011 0241 Spring Pin 3 26 44 A0712 1261 Release Catch Guide 45 A0100 0461 Spring 46 A0000 0031 Screw M4 3 5 47 A0711 2831 Release Catch B 48 A0714 0671 Adjustment Wheel 4...

Page 13: ...Wheel 71 A0006 0451 Guide Pin 72 A0707 0741 Pusher Site 73 A0101 0161 Spring 74 K0300 3181 Head Valve Assembly 75 K0600 1891 Piston Unit 76 K0300 3561 Cylinder Set 77 K0300 3201 Spacer Set 78 A0307 0041 Air Plug MODEL NUMBER 870013 AIR PRESSURE 70 120 PSIG 5 0 8 5 kg cm2G NAIL LENGTH 1 1 4 12 5 mm 2 1 2 25 mm NAIL CAPACITY 110 NAILS MINIMUM HOSE DIAMETER 1 4 6 5 mm NAIL DIAMETER 15 GAUGE NET WEIGH...

Page 14: ... SNAP ON portable air tool and no one else all parts of the product except those parts referred to below which are specifically excluded from such warranty see Exclusions to be free from defects in materials and workmanship for a period of one year from the original date of purchase The date of purchase shall be the date of shipment to the original purchaser or the date the original purchaser took...

Page 15: ...HTS CLAIMS AND OR CAUSES OF ACTION ARISING THEREFROM OR BASED THEREON PURCHASER S SOLE AND EXCLUSIVE REMEDY IS AS STATED ON PRECEDING PAGES LIMITATIONS OF LIABILITY IN NO EVENT SHALL ALLTRADE AND OR ITS REPRESENTATIVE S BE LIABLE FOR INDIRECT INCIDENTAL SPECIAL AND OR CONSEQUENTIAL DAMAGES OF ANY KIND ARISING OUT OF OR RELATED TO DIRECTLY OR INDIRECTLY ANY BREACH OR PROVISION OF ANY AGREEMENT BETW...

Reviews: