background image

TROUBLESHOOTING GUIDE

1. Do not wash in washing machine or immerse the product or the adapter in water.

2. Always switch off before cleaning and remove the adapter from the socket with clean, 

    dry hands.

3. The massager should be wiped with a slightly moist cloth and dried thoroughly. 

    

Do not wipe the product with alcohol or harsh chemicals such as thinner or bleach.

4. Do not overstretch the eAlas�c back straps.

5. Keep away from heat, fire or exposure to direct sunlight.

6. Do not apply excessive pressure or impact onto massager/massage heads. 

    Applica�on of a direct force in excess of 110 lbs. may damage your massager and 

    invalidate your warranty. Refrain from over usage of the device.

7. Store the massager in a cool, dry place out of reach of children. 

8. Avoid contact with sharp edges or pointed objects which might cut or puncture 

    the cover of massager.

Massage heads rota�ng at 

reduced speed. 

Massage heads only rotate in

the upper or lower region.  

Device switches off suddenly  

Jerky mo�on of massage 

heads /Vibra�ons from device 

Excessive pressure may have been applied 

onto the device.Reduce the load and try again.
Device may be jammed. Remove pressure / 

loadfrom the device and press the 'Full Back' 

bu�on to try again.

Infra-red lights are on but no

mo�on from massage heads  

Fault

Solutions

The load on the massage hea ds is excessive. 

Reduce load and try again.  
The massage has been ac�vated for the upper 

or lower back region. Press the 'Full Back' 

bu�on for the massage to cover both regions. 

Device may have been in use for 15mins. 

Auto-shut-off func�on ac�vated. Con�nue 

using by pressing the ‘power’ bu�on a�er 

res�ng the unit for 15mins. 
Over-heat protec�on func�on ac�vated. 

Device is switched off for your safety. Please 

rest device for 15-30mins before restar�ng. 

Check if adapter is plugged into socket. 
Check if adapter output is connected to 

device power inlet wire.  

Check if device has been used for more than 

15mins. If so, let device rest for 15mins 

before con�nuing. Device may require longer 

�me to cool in warmer environments.   

Device fail to start

6

Care and Cleaning Instruc�ons

Summary of Contents for SL-256

Page 1: ...Use care manual SHIATSU MASSAGE CUSHION WITH HEAT SL 256 ...

Page 2: ...must be replaced by the manufacturer a service representa ve or by qualified personnel In case of malfunc on disconnect immediately from the mains Do not use if you have skin disorders open wounds or swollen or inflamed areas Misuse or incorrect use excludes any liability for damage Do not use this device while driving Do not use while you sleep In order to avoid excessively s mula ng the muscles an...

Page 3: ...nk you for purchasing Shiatsu massage cushion with heat by Snailax Corpora on With normal care and proper treatment it will provide years of reliable service Please read all instruc ons carefully before using this product Please retain this manual for future reference FEATURES Full back Shiatsu massage Flexible massage nodes Spot massage Soothing heat therapy Seat vibra on massage Intensity contro...

Page 4: ...n nuous massage of 15 Minutes per me and Not exceed 3 mes use one day The device will automa cally switch off a er 15 minutes mer run out Remove the adapter from the outlet when not in use Do not setup or use the massager in a bathroom or similary wet damp areas Blanket Towel Install the flap onto the cushion to get a so er massage Place a blanket or towel between you and the massager to achieve a f...

Page 5: ...vibra on You may cycle through low medium high and off se ngs Heat Button Press to ac vate heat The heat cannot be turned on if the massage func on is not ac vated Timer Button Press to set the massage me at 5 10 or 15 minutes Demo Button Quick demonstra on of the different func ons The L E D lights will blink to indicate the ac ve func ons Once complete the device willautoma cally turn off Power But...

Page 6: ... region Device switches off suddenly Jerky mo on of massage heads Vibra ons from device Excessive pressure may have been applied onto the device Reduce the load and try again Device may be jammed Remove pressure loadfrom the device and press the Full Back bu on to try again Infra red lights are on but no mo on from massage heads Fault Solutions The load on the massage hea ds is excessive Reduce loa...

Page 7: ...will be given to any force majeure and man made causes to a defec ve product such as improper care personal tear down and willful damage etc If you have any issue about the product please feel free to contact us by sending email to support snailax com We will strive to provide the best service possible within 24 hours Tel 734 709 6982 Monday Friday 9 00AM 4 30PM Email support snailax com Extend Wa...

Page 8: ...television recep on which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separa on between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the deale...

Reviews: