199
| SMSEagle MHD-8100
| User’s Manual
NET-SNMP-EXTEND-MIB::nsExtendOutputFull."FolderSent_Last24H" = STRING: 0
NET-SNMP-EXTEND-MIB::nsExtendOutputFull." FolderSent_Last24HSendErr" = STRING: 0
EXAMPLE OF BROWSING SMSEAGLE EXTENSION PARAMETERS IN MIB TREE USING MIB-BROWSER
Setting up SNMP v3 access control
By default, SMSEagle devices uses SNMP v2 access control. Using v3 can strengthen security, however is
not mandatory. To easily switch to SNMP v3 access control we’ve prepared special shell script located at
/opt/smseagle
directory.
1.
Log in via SSH using root account
2.
Navigate to:
cd /opt/smseagle/
3.
Configuration script:
./snmpv3
4.
Script can run with following parameters:
i.
add
ii.
del
iii.
enablev2
iv.
disablev2
5.
To add v3 USER please run:
./snmpv3 add USERNAME PASSWORD ENCRYPTIONPASSWORD