LAN9512 Evaluation Board User Manual
Revision 1.0 (05-21-09)
USER MANUAL
SMSC LAN9512
4
2.1
Jumpers
describes the default settings and jumper descriptions for the EVB9512. These defaults are
the recommended configurations for evaluation of the LAN9512. These settings may be changed as
needed, however, any deviation from the default settings should be approached with care and
knowledge of the schematics and datasheet. An incorrect jumper setting may disable the board.
Note:
A dashed line in the
Settings
column of
indicates the board’s default jumper setting.
2.2
LEDs
Table 2.1 Jumpers
JUMPER
DESCRIPTION
SETTINGS
JP1
5 volt select jumper
1 2
Populate when bus-powered
2---3
Populate when self-powered
(+5V power brick must be attached)
JP9
Auto-MDIX jumper
1---2
Auto-MDIX enabled
2 3
Auto-MDIX disabled
JP22
VBUS_DET jumper
1 2
Populate when bus-powered
2---3
Populate when self-powered
JP27
CLK24_EN jumper
1 2
Populate to enable 24MHz CLK24_OUT
2---3
Populate to disable 24MHz CLK24_OUT
Table 2.2 LEDs
REFERENCE
COLOR
INDICATION
LED3
Green
+3.3V power active
LED4
Green
Power on downstream port 2
LED5
Green
Power on downstream port 3
LED8
Green
Full duplex on Ethernet port
T1
Green
Link/activity on Ethernet port
T1
Yellow
Speed on Ethernet port