Smoky Mountain 3495GLA Assembly And Owner'S Manual Download Page 18

18

Valve/pressure regulators are factory set to 

the correct operating pressures. NO attempts   

          should be made to adjust these settings.

Connecting the LP Gas Cylinder:

1. The valve on the LP cylinder must be closed. See 

that the knob is turned clockwise to a full stop.

2. Check that the control knob on the smoker is 

turned OFF.

3. Remove the protective cap from the LP Cylinder 

valve and coupling nut, if present.

4. Hold the regulator in one hand and insert the 

nipple into the valve outlet. Be sure the nipple 

is centered in the valve outlet. The coupling nut 

connects to the large outside threads on the 

valve outlet, Use care - DO NOT cross thread the 

connection.

5. Hand tighten the coupling nut clockwise until it 

comes to a full stop. Firmly tighten by hand only. 

DO NOT USE TOOLS.

CAUTION:

 I

n the connection process, the 

regulator side of the connection will seal on 

the back check in the valve, resulting in a slight 

resistance. The connection requires about one-

half (1/2) to  three-quarters (3/4) additional turn to 

complete the connection.

When setting up the smoker and cylinder, it is 

recommended to have the cylinder and the smoker 

on a line perpendicular to the wind direction.

The gas hose/regulator assembly should be totally 

extended to the maximum distance so that the hose 

is straight and the cylinder is as far from the smoker 

as it can be. LP cylinders are intended for operation 

in the upright position only.

Care should be taken to protect the fuel supply hose 

from damage by either foot or vehicle traffic.

If the smoker is not in use, the gas must be turned 

off at the LP cylinder and the cylinder should be 

disconnected from the smoker and stored away 

from the smoker.

Storage of the smoker indoors is only permissible if 

the LP cylinder is disconnected and removed from 

the smoker.

LP cylinder must be stored outdoors out of reach 

of children and pets, and must not be stored in a 

building, garage or any other enclosed area.

Leak Testing (Check for gas leaks)

After all connections are completed, check all connections 

and fittings for leaks with a soap solution.

* Mix dish soap with water (about 3:1 mix ratio)

* With all valves closed, apply the soap solution to all   

   gas flow connections and fittings.

* Open LP Cylinder valve about 1 -1/2 turn.

Presence of bubbles at areas of wet solution

indicates a gas leak.

If leaks are detected or you smell or hear gas, shut 

off the valve and repair the leak or replace the 

defective part. 

DO NOT USE THE SMOKER UNTIL 

ALL LEAKS ARE CORRECTED.

CONNECTING THE LP CYLINDER

WARNING

ALL INSTRUCTIONS AND SAFEGUARDS ON THIS PAGE MUST BE

FOLLOWED TO PREVENT FIRE, DAMAGE AND/OR INJURY.

!

!

DANGER

!

24"Min

(61cm)

3495GLA, 3895GLA, 3895GWLA_MI V1 20180511.indd   18

2018/5/11   12:28:20

Summary of Contents for 3495GLA

Page 1: ...M of any other gas cylinder 3 Never operate this appliance within 25 feet 7 5m of any flammable liquid ASSEMBLER INSTALLER Leave these instructions with the consumer CONSUMER USER This instruction man...

Page 2: ...e want you to be completely satisfied with your purchase For your future records please fill in Model ____________________________________ Serial _____________________________________ Date of Purchase...

Page 3: ...structure or combustible material DO NOT operate the smoker under overhead construction Keep the fuel supply hose away from any heated surface Operate the smoker only on stable level non flammable sur...

Page 4: ...ces and the products of combustion of such fuels can expose you to chemicals including carbon black which is known to the state of the california to cause cancer and carbon monoxide which is known to...

Page 5: ...odor is accounted for DO NOT use the smoker if the burner fails to light or fails to remain lit Under such conditions the gas should be cut off and the fuel cylinder should be disconnected DO NOT oper...

Page 6: ...arts are damaged please call our toll free customer service line to order parts 1 800 321 3473 DO NOT RETURN YOUR SMOKER TO THE RETAILER PLEASE CALL US FIRST Model 3495GLA Hardware List A 28X M6X12 8X...

Page 7: ...BLY 1 5 LOCK PLATE 1 6 TEMPERATURE GAUGE ASSEMBLY 1 7 DOOR PANEL 1 8 HANDLE ASSEMBLY 3 9 SIDE HANDLE STEEL 7 2 10 DAMPER PLATE with plastic tip guards 2 11 CONTROL PANEL ASSEMBLY 1 12 STEEL TUBE LEG 2...

Page 8: ...are damaged please call our toll free customer service line to order parts 1 800 321 3473 DO NOT RETURN YOUR SMOKER TO THE RETAILER PLEASE CALL US FIRST Model 3895GLA 3895GWLA Hardware List A 28X M6X...

Page 9: ...PANEL 1 8 HANDLE ASSEMBLY 3 9 SIDE HANDLE STEEL 7 2 10 DAMPER PLATE with plastic tip guards 2 11 CONTROL PANEL ASSEMBLY 1 12 STEEL TUBE LEG 2 13 STEEL TUBE LEG with eyebolt insert 2 14 BURNER ASSEMBLY...

Page 10: ...10 Assembly Steps Step 1 Step 2 A 4X M6X12 Step 3 A 4X M6X12 Step 4 B 2X M5X12 3495GLA 3895GLA 3895GWLA_MI V1 20180511 indd 10 2018 5 11 12 28 14...

Page 11: ...tab that goes inside the Butterfly holes is specifically designed to keep vent partially open at all times This is a safety feature required in all Smoky Mountain Vertical Smokers B 2X M5 E 2X 5 F Pl...

Page 12: ...12 Assembly Steps Step 8 A 8X M6X12 Step 9 B 2X M5X12 8X M6 D 8X 6 G Step 10 A 3X M6X12 3495GLA 3895GLA 3895GWLA_MI V1 20180511 indd 12 2018 5 11 12 28 16...

Page 13: ...13 Assembly Steps Step 11 C 1X M5X8 Step 12 Step 13 ZIP TIE ZIP TIE Step 14 3495GLA 3895GLA 3895GWLA_MI V1 20180511 indd 13 2018 5 11 12 28 16...

Page 14: ...14 Assembly Steps Step 15 A 2X M6X12 Step 16 B 2X M5X12 2X M6 D 2X 6 G M6 4X D 6 4X G A M6X12 4X 3495GLA 3895GLA 3895GWLA_MI V1 20180511 indd 14 2018 5 11 12 28 17...

Page 15: ...15 Assembly Steps This step only for Model 3895GLA 3895GWLA Step 17 Step 18 3495GLA 3895GLA 3895GWLA_MI V1 20180511 indd 15 2018 5 11 12 28 19...

Page 16: ...16 Assembly Steps Step 19 Model 3495GLA Model 3895GLA 3895GWLA 3495GLA 3895GLA 3895GWLA_MI V1 20180511 indd 16 2018 5 11 12 28 20...

Page 17: ...ll If instructions A and B above are not followed exactly a fire causing death or serious injury may occur Cylinders must be filled before initial use All handling transport filling and storage of LP...

Page 18: ...tance so that the hose is straight and the cylinder is as far from the smoker as it can be LP cylinders are intended for operation in the upright position only Care should be taken to protect the fuel...

Page 19: ...in the next few sections of this manual Using your desired flavoring woods and marinades add water in the water pan burn your smoker at the lowest temperature by setting your control knob to LOW and...

Page 20: ...d quantities of wood chunks chips or sticks You can also mix woods Most smoker flavoring occurs within the first hour of cooking Adding wood chips after the first hour is typcially not necessary unles...

Page 21: ...ir may have settled near the burner during the initial lighting attempt Prior to attempting to relight the burner fan out the bottom of the cabinet of existing air Then repeat the above lighting steps...

Page 22: ...er with space between each piece This will allow smoke and hot moisture to circulate evenly around the food pieces Depending on meat and size smoking for 2 to 3 hours at the ideal constant cooking tem...

Page 23: ...amb 160 F 71 C Beef Pork 160 F 71 C Fresh Beef Medium Rare 145 F 63 C Medium 160 F 71 C Well Done 170 F 77 C Fresh Lamb Medium Rare 145 F 63 C Medium 160 F 71 C Well Done 170 F 77 C Fresh Pork Medium...

Page 24: ...o cool completely before handling If you must handle the smoker while it is hot ALWAYS wear protective oven mitts or heat resistant gloves when handling the smoker or its components Allow the smoker t...

Page 25: ...and use heavy duty heat resistant paint to cover affected area NEVER APPLY additional paint to the interior of the smoker If rust is present on the interior of the smoker clean thoroughly with steel...

Page 26: ...26 Model 3495GLA Replacement Parts 3495GLA 3895GLA 3895GWLA_MI V1 20180511 indd 26 2018 5 11 12 28 21...

Page 27: ...2 CONTROL PANEL ASSEMBLY Rotary 14000BTU 1 AZ002126 13 STEEL TUBE LEG 2 AZ001106 14 STEEL TUBE LEG with eyebolt insert 2 AZ001105 15 BURNER ASSEMBLY 1 AZ002205 16 WOOD CHIP BOX DRAWER 1 AZ002128 17 ST...

Page 28: ...28 Model 3895GLA Replacement Parts 3495GLA 3895GLA 3895GWLA_MI V1 20180511 indd 28 2018 5 11 12 28 21...

Page 29: ...EL ASSEMBLY Rotary 16000BTU 1 AZ002082 13 STEEL TUBE LEG 2 AZ001106 14 STEEL TUBE LEG with eyebolt insert 2 AZ001105 15 BURNER ASSEMBLY 1 AZ002207 16 WOOD CHIP BOX DRAWER 1 AZ002084 17 STEEL WOOD CHIP...

Page 30: ...30 Model 3895GWLA Replacement Parts 3495GLA 3895GLA 3895GWLA_MI V1 20180511 indd 30 2018 5 11 12 28 21...

Page 31: ...NEL ASSEMBLY Rotary 18000BTU 1 AZ002089 13 STEEL TUBE LEG 2 AZ001106 14 STEEL TUBE LEG with eyebolt insert 2 AZ001105 15 BURNER ASSEMBLY 1 AZ002206 16 WOOD CHIP BOX DRAWER 1 AZ002208 17 STEEL WOOD CHI...

Page 32: ...ped at no charge via the discretion of the Customer Service Department ground shipments US Mail or Parcel Post ONLY Any special handling charges i e Second Day Overnight etc will be the responsibility...

Reviews: