4

FIGURE 2

IV. INSTALLATION

NOTE: This product has been designed specifically

for commercial and residential applications
such as offices, conference rooms, cafeteria
and living areas. United Air Specialists
assumes no responsibility for those applica-
tions unlike the aforementioned.

The SMOKEETER/CRYSTAL-AIRE is designed to
draw the contaminated air through the unit and
exhaust clean air back into the room. The clean 
air is used to push contaminated air around the 
room to the inlet of the unit. Directions of air 
patterns and proper placement of the unit should 
be established by your local SMOKEETER/
CRYSTAL-AIRE distributor or by United Air
Specialists, Inc.

The SMOKEETER/CRYSTAL-AIRE can be installed
by:

1. Placing on desk, file cabinet or other stable surface.

2. Mounting on a wall.

CAUTION: Power connection — The power cord

on this product should be used in con-
nection with a properly-sized and
appropriately located 115 VAC ground-
ed outlet receptacle. No alteration of
the power cord should be attempted
nor should extension cords be used.

To  reduce the risk of electric shock,
this equipment has a grounding-type
plug that has a third (grounding) pin.
This plug will only fit into a grounding-
type power outlet. If the plug does not
fit into the outlet, contact qualified
personnel to install the proper outlet.
Do not alter the plug in any way.

WALL MOUNTING OPTION

A wall mounting bracket is provided for mounting 
the unit on walls.

Securely attach the wall mounting bracket against
the wall, allowing 2

1

2

" from the ceiling for clearance

of the unit (see Figure 2).

WARNING: Use fasteners and anchoring devices that

will ensure support of the 27 pound unit.

After the mounting bracket is attached, remove the
unicell assembly from the cabinet to facilitate
handling and lighten the weight (see Removing
Components — page 5).

Slide the keyhole slots in the unit base over the 
studs on the wall bracket and allow the base to drop
into place, resting on the studs. Using the screw 
provided with the unit, secure the base to the moun-
ting bracket.

The SMOKEETER/CRYSTAL-AIRE should now be
tested for secure support.

Reinstall the components and attach the cabinet.

Plug the unit into a grounded 115 volt AC outlet.

REVERSING AIRFLOW

The unit is shipped to you ready for installation 
in a left-to-right airflow configuration. If a right-
to-left airflow is desirable, simply turn unit 180°
(unit will be upside down). Remove plastic logo and
place upright in same position (logo is now located in
upper left).

V.

OPERATION

For best results and to assure maximum air quality,
your SMOKEETER/CRYSTAL-AIRE should be 
started before the air becomes contaminated. An
indicator lamp on the unit is illuminated during 
normal operation of both the power pack and the 
unicell and will dim when the unicell requires 
servicing. A solid-state speed control switch allows
you to adjust the fan speed. If you notice a decrease
in cleaning efficiency, increase the fan speed to
increase the unit’s effectiveness.

FOR YOUR INFORMATION — Each SMOKEETER/
CRYSTAL-AIRE has been thoroughly tested prior to
shipment from the factory. Even so, there may 
be some initial arcing of the components at start 
up. The noise should cease after a few minutes 
of operation.

Summary of Contents for SE 10

Page 1: ...Electronic Air Cleaner MODEL SE 10 OWNER S MANUAL To Place an Order Call ACS Inc 800 878 5030 ...

Page 2: ...R CORD 10 16 ga with molded grounded plug POWER CONSUMPTION 104 Watts Max AIR HANDLING CAPACITY 90 to 250 CFM WEIGHT HANGING 27 lbs 10 KG SHIPPING 32 lbs 12 KG DIMENSIONS Height Width Length 13 12 171 4 33 cm 30 5 cm 43 8 cm SPECIFICATIONS MODEL SE 10 ...

Page 3: ...NFORMATION IS PROVIDED FOR TRAINED SERVICE PERSONNEL ONLY VII Periodic Maintenance and Troubleshooting 6 VIll Replacement Parts 8 IX Illustrated Parts 10 Unicell Assembly 12 Wiring Diagrams 13 IMPORTANT NOTICE BEFORE OPERATION PLEASE REMOVE ALL PACKING MATERIAL FROM INSIDE UNIT THIS CAN INCLUDE MARKED TIE DOWN SCREWS CARDBOARD STYROFOAM AND PLASTIC WRAP ON CARBON FILTER MODELS VARY IN MATERIAL USE...

Page 4: ... claim if any damage is found Before operating unit remove all packing material including carbon afterfilter packaging and unicell shipping screws III HOW YOUR SMOKEETER CRYSTAL AIRE OPERATES The air mover draws air through the ionizer As par ticles pass through the ionizer section they are given an intense positive charge These charged particles are then collected on cell plates The clean air is ...

Page 5: ... 21 2 from the ceiling for clearance of the unit see Figure 2 WARNING Use fasteners and anchoring devices that will ensure support of the 27 pound unit After the mounting bracket is attached remove the unicell assembly from the cabinet to facilitate handling and lighten the weight see Removing Components page 5 Slide the keyhole slots in the unit base over the studs on the wall bracket and allow t...

Page 6: ... inside cabinet The unicell and cabinet should be cleaned periodically to assure continued efficiency Cleaning may be required from once a month to once every four months depending on the air quality NOTE The carbon filter cannot be cleaned and needs to be replaced once every six to 12 months 1 The unicell can be cleaned by soaking in a hot solution of SMOKEETER CRYSTAL AIRE brand detergent for 30...

Page 7: ... baffle plates parallel to the wire are at ground potential Its function is to electrically charge the contaminated particles as they pass through it 3 Unicell Collecting Section the collecting section consists of alternately charged plates Plates are alternately charged with a nominal 5 500 volts DC positive The field between the plates forces the charged particles to the ground plates and remove...

Page 8: ...t speed control switch on and cautiously engage the safety interlock switch by depressing the button CAUTION Be sure to disengage safety interlock switch after measuring voltages 4 Place the probe s tip on the ionizer and measure the positive DC voltage The voltage should read 10 0 to 11 0 KV DC If measurements are abnormal refer to the troubleshooting guide for cause and correction If measurement...

Page 9: ...TED AIR SPECIALISTS INC 4440 CREEK ROAD CINCINNATI OHIO 45242 1 800 551 5401 ATTN SMOKEETER CRYSTAL AIRE CUSTOMER SERVICE The following information will be required for prompt service 1 Unit Model No on bottom of base unit at air mover end 2 Unit Serial No on bottom of base unit at air mover end 3 Part No of part see Section IX Illustrated Parts When returning a defective part under warranty you m...

Page 10: ...lock defective switch 4 Control switch defective 4 Replace control switch D Air mover operates on 1 Control switch defective 1 Replace control switch low or high speed only E Poor air quality 1 Unicell dirty 1 Clean unicell 2 Unicell malfunctioning 2 Check unicell for a Foreign matter between plates b Ionizer wire loose or broken c Defects in insulators 3 Unicell installed 3 Install unicell as sho...

Page 11: ...10 IX ILLUSTRATED PARTS ...

Page 12: ...POWER PACK 90 130V 1 21 1246 POWER PACK 200 250V 1 10 30 0537 TINNERMAN NUT 2 11 36 0072 LEAF SPRING INTERLOCK ACTUATOR 1 12 36 0014 CONTACT SPRING COIL 1 13 10 3491 FAN COVER 1 14 32 0156 ALUMINUM PROPELLER 1 15 02 2625 MOTOR ASSEMBLY 1 16 20 1314 LED INDICATOR 1 17 CHOOSE 1 03 1513 SPEED CONTROL VARIABLE SPEED UNITS 1 20 1421 ROCKER SWITCH 2 SPEED UNITS 1 18 20 1368 GROUNDBUS 1 19 20 2922 CORD 1...

Page 13: ...20 8 9 10 2811 CORNER ANGLE 2 10 02 2721 IONIZER WIRE ASSEMBLY 4 11 36 0037 IONIZER WIRE SPRING 8 12 37 0013 INSULATOR CERAMIC 4 13 30 0039 LOCKWASHER 8 INT TOOTH 8 14 30 0119 SCR PAN HD 8 32x5 16 LG 8 15 18 0795 IONIZER RAIL TOP WITH H V CONTACT 1 16 10 2786 IONIZER RAIL BOTTOM 1 17 37 0064 UNICELL MASK 1 18 30 0283 CELL SPACER WASHER 4 19 20 1312 TERMINAL CELL 1 20 20 1313 TERMINAL IONIZER 1 To ...

Page 14: ...13 WIRING DIAGRAMS SE 10 230 VAC 2 Speed SE 10 120 VAC Variable Speed ...

Page 15: ......

Page 16: ...ot manufactured by UAS THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORAL OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT As Purchaser s exclusive remedy for any defects in the equipment UAS will exchange or repair any defective parts during the warranty period provided such parts are returne...