Commissioning 

 
1. Turn on the electrical supply at the fused spur. 
 
2. Set the upper control switch on the fascia grille to 
BLUE and the lower switch to either l or ll. The fan 
will run. 
 
3. Turn on the central heating system. 
 
4. Set any room thermostat/s to maximum. 
 

5. Set the lower heat output switch to l and the 
upper switch to RED – the fan should run and heat 
will flow within a few minutes. 
 
6. Balance the central heating system if Space Saver 
is installed on the same circuit as panel radiators. 
 
7. When the installation is working correctly, 
remember to reset any room thermostat/s to its 
normal setting 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 

 
 

 

 

 
 

 

 
 

 

 

 
 

 

 

 
 

 

 

 
 

 

Fault Finding 

 

 

 

 
 

 

 

 
 

 

 

 
 

 

 
 

 

 

 

 

 

 

 
 

 

 

HOSE 

BEND RADIUS 

60mm MIN 

 

Electrical Cable 

Plinth 

5. Position heater, making sure the 
flexible hoses are not kinked and the 

electrical cable is not snagged. 

l

 

6a. Fit supplied grille over top flange, locate over 
switches then press lower edge backwards as 
shown in diagram to fix in place. 

l

 

6b. Fix assembled heater to plinth using 
fixing screw holes located at either end 

of grille. 

Grille to plinth securing screws 

Heat Output Perormance 

 

It is recommded that the Space Saver model chosen is capable of maintaning the calculated heat loss 
at normal heat output (l) enabling the boost setting (ll) to be used for faster heat up. 
 

 

Heat Output Δt 60°C 

Heat Output Δt 50°C 

Model 

Normal 

(kW) 

Boost 

(kW) 

Normal 

(kW) 

Boost 

(kW) 

  

SS3 

0.8 

0.9 

0.6 

0.8 

SS5 

1.3 

1.7 

1.1 

1.4 

SS7 

1.6 

1.9 

1.3 

1.6 

SS9 

2.2 

2.4 

1.9 

2.1 

 

Notes: 

 

Δt 60°C assumes a mean water temperature of 80°C and room temperature of 20°C. 

 

Δt 50°C assumes mean a water temperature of 70°C and room temperature of 20°C. 

1. Fan does not run on any switch 
setting. 

a). Check the power supply is switched ON. 
 
b). Check fuse in fused spur. 
 
c). Check the wiring connections at the fused spur. 
 
 
 

2. No heat output on settings l and ll. 

a). Check the power supply is switched ON. 
 
b). If fitted, ensure any room thermostats are calling   
for heat. 
 
c). Balance the central heating system if installed  on 
same dircuit as panel radiators and increase the 
circulating pump speed if required. 
 
d). Increase the boiler water temperature. 

 

 

In the event of any difficulty, please contact us on 01245 324560. 

It will be more helpful if you do not remove the product fro the central heating system. 

 