Commissioning
1. Turn on the electrical supply at the fused spur.
2. Set the upper control switch on the fascia grille to
BLUE and the lower switch to either l or ll. The fan
will run.
3. Turn on the central heating system.
4. Set any room thermostat/s to maximum.
5. Set the lower heat output switch to l and the
upper switch to RED – the fan should run and heat
will flow within a few minutes.
6. Balance the central heating system if Space Saver
is installed on the same circuit as panel radiators.
7. When the installation is working correctly,
remember to reset any room thermostat/s to its
normal setting
4
Fault Finding
5
HOSE
BEND RADIUS
60mm MIN
Electrical Cable
Plinth
5. Position heater, making sure the
flexible hoses are not kinked and the
electrical cable is not snagged.
l
6a. Fit supplied grille over top flange, locate over
switches then press lower edge backwards as
shown in diagram to fix in place.
l
6b. Fix assembled heater to plinth using
fixing screw holes located at either end
of grille.
Grille to plinth securing screws
Heat Output Perormance
It is recommded that the Space Saver model chosen is capable of maintaning the calculated heat loss
at normal heat output (l) enabling the boost setting (ll) to be used for faster heat up.
Heat Output Δt 60°C
Heat Output Δt 50°C
Model
Normal
(kW)
Boost
(kW)
Normal
(kW)
Boost
(kW)
SS3
0.8
0.9
0.6
0.8
SS5
1.3
1.7
1.1
1.4
SS7
1.6
1.9
1.3
1.6
SS9
2.2
2.4
1.9
2.1
Notes:
Δt 60°C assumes a mean water temperature of 80°C and room temperature of 20°C.
Δt 50°C assumes mean a water temperature of 70°C and room temperature of 20°C.
1. Fan does not run on any switch
setting.
a). Check the power supply is switched ON.
b). Check fuse in fused spur.
c). Check the wiring connections at the fused spur.
2. No heat output on settings l and ll.
a). Check the power supply is switched ON.
b). If fitted, ensure any room thermostats are calling
for heat.
c). Balance the central heating system if installed on
same dircuit as panel radiators and increase the
circulating pump speed if required.
d). Increase the boiler water temperature.
In the event of any difficulty, please contact us on 01245 324560.
It will be more helpful if you do not remove the product fro the central heating system.