background image

If you have damaged or missing components please contact customer service. 

800-328-1061

www.smithsystem.com

 

Page 2 of 6 

    P/N: 179993 

3.

Install LIFTING COLUMN, 70153 PLT (or 70161 PLT), as shown using (4) provided machine
screws.  Ensure column is installed with cable pointing in correct direction as shown.

4.

Install Activating Lever (attached to LIFTING COLUMN) using provided wood screws and
cable clip.  The top should have predrilled holes that identify proper location of the activating
lever.  The cable clip needs to be only 2

½” to 3” away from the handle in order to prevent cable

from jumping out of place on the handle.

Reviews: