1. Set the POWER switch to
the OFF or down position
(Fig. 1, 1).
2. Set the OUTPUT VOLTAGE
ADJUST control to the
extreme counter-clockwise
position (Labeled
MIN
.)(Fig.
1, 2).
3. Attach foot switch (or other
control device) (Fig. 2, 3).
4. Connect the electrodes
to be used to the desired
output connector (Fig. 2, 4).
5.
Connect the AC INPUT 230
VAC connector to the AC
power source (generator)
(Fig. 2, 5).
6.
Set the OUTPUT (range)
switch to the desired posi-
tion (Fig. 1, 6).
SET-UP INSTRUCTIONS
7.
Select desired DUTY CYCLE
& FREQUENCY, (Cont. DC or
pulsed DC are selected at this
step) (Fig. 1, 7).
BEGIN ELECTROFISHING
1.
Start the generator.
2.
Toggle power circuit
breaker ON.
3.
Put the Emergency Stop
switch in the on position.
4.
Depress foot switch or
anode pole thumb switch.
5.
Increase output by rotating
OUTPUT ADJUST CON-
TROL in a clockwise move-
ment.
6.
During operation, before
changing OUTPUT (range)
switch, set the OUTPUT
ADJUST control to the
extreme counter- clockwise
position (MIN.) and release
footswitch(s)/pole switch(s)
7.
Make sure that the front
cover is closed during
actual electrofishing oper-
ations and keep the front
panel safe from splashes
and rainy weather.
SECONDS
INPUT VOLTS AC
DUTY CYCLE
OUTPUT FREQUENCY
ON
600V
300V
OFF
VOLTAGE ADJUST
MIN.
MAX.
OUTPUT AMPS
OUTPUT VOLTS
OVERLOAD
ANODE 1
ANODE 1 & 2
OUTPUT ON
OUTPUT OFF
www.smith-root.com
Vancouver, Washington, USA
VARIABLE VOLTAGE PULSATOR
VVP
-
15C
ELECTROFISHER
50
55
45
10
60
40
20
70
35
25
15
5
80
90
120
30
CPS
3 PULSE
50
55
10
60
45
40
20
70
35
25
OFF
CONT. DC
80
30
2
6
7
1
Fig. 1