Smith-Root VVP-15B User Manual Download Page 4

2

2008

VVP-15B

ELECTROFISHER

FRONT PANEL CONTROLS:

1 - INPUT/OUTPUT VOLTAGE METER:

 indicates the AC input voltage, the AC output voltage, or the DC modes output voltage.

 

AC voltage is measured as a RMS value and DC voltage is measured at an average peak value.

2 - OUTPUT CURRENT METER:

 indicates output current.

3 - METER SELECT CONTROL:

 selects the desired input or output voltage to be measured.

4 - OUTPUT ADJUST CONTROL:

 Output voltage from the Model VVP-15B can be varied from 0 Volts to Maximum Volts of selected 

Range (may be limited by load conditions and overload protection) for all outputs—AC, DC, and Pulsed DC (CPS included).

5 - OUTPUT STATUS
 

OUTPUT ON:

 green indicator light indicates that the output from the unit is ON. 

 

OUTPUT OFF:

 red indicator light indicates that the output from the unit is OFF.

6 - AC INPUT 230 VAC:

 connector is the AC input power connector.

7 - POWER:

 is the main power switch and circuit breaker.

8 - OUTPUT RANGE SELECT:

 switch selects either 300 or 600 as maximum output voltage.

12

13

10

11

1

2

3

4

5

6

7

8

9

Summary of Contents for VVP-15B

Page 1: ...USER S MANUAL VVP 15B Electrofisher 07955 012...

Page 2: ...y Credit Refund Policy Customers returning equipment in new condition will be given credit within five days from the date of the return A return authorization must accompany returns Valid equipment re...

Page 3: ...allow consistency with previous samplings Higher efficiency is an added benefit of our Generation B allowing increased samples with less wear and tear on equipment Input and output connectors remain...

Page 4: ...Output voltage from the Model VVP 15B can be varied from 0 Volts to Maximum Volts of selected Range may be limited by load conditions and overload protection for all outputs AC DC and Pulsed DC CPS i...

Page 5: ...s for 196 standard pulse mode options with duty cycles between 10 and 80 and frequencies between 5 and 120 Hz The CPS modes have 3 pulses per burst and 6 pulses per burst options that work in combinat...

Page 6: ...ging OUTPUT range switch MODE switch or selected electrode output from one output to another set the OUTPUT ADJUST control to the extreme counter clockwise position MIN and release footswitch s pole s...

Page 7: ...cs Indicator ON LIGHT will turn off and Indicator OFF LIGHT will turn on Output will be disabled VVP 15B will not reset after three seconds Correction Turn off the ON OFF circuit breaker Return VVP 15...

Page 8: ...e entry of water into the waders 11 Use only dip nets with non conductive handles Never use an anode as a net as it is extremely dangerous to other members of the crew and can cause severe injury to a...

Page 9: ...AC AC 300 VOLTS AC OUT DC OUTPUT AC OUTPUT 15 CPS 3 PULSE DC 300 OR 600 DC OUT AC OUTPUT DC OUTPUT 30 CPS 3 PULSE DC 300 OR 600 DC OUT AC OUTPUT DC OUTPUT 45 CPS 3 PULSE DC 300 OR 600 DC OUT AC OUTPUT...

Page 10: ......

Page 11: ...this limited warranty d The Consumer will be billed for any parts or labor charges not covered by this limited warranty The Consumer will be responsible for any expenses related to reinstallation of t...

Page 12: ......

Page 13: ......

Page 14: ......

Reviews: