Smith-Root UBC-24 User Manual Download Page 9

07292.13 UBC-24 Man

USER'S GUIDE

UBC-24

U N I V E R S A L   B A T T E R Y   C H A R G E R

www.smith-root.com

SPECIFICATIONS

Input Rating:

Nominal 90-264VAC/47-63Hz

Maximum Output Power:

60W

Load Regulation:

<200mV

Line Regulation:

<100mV

Switch Frequency:

≈40 kHz

Temperature Range:

-10°C to +40°C

Ripple:

<100mVp-p

Efficiency (At 100% 

Load):

80%

Insulation Class:

Class I

Electrical Safety:

UL 60601-1, EN 60601-1, EN 
60950, EN 60335-2-29

EMC Standards:

EN 60601-1-2 (Medical), EN 
61000-6-3 (Emission), EN 
61000-6-1 (Immunity)

Timer:

2hr 330% (also available with 
other values)

Input Connection:

3 pin IEC 320 (input cordset 
not included)

Output Connection:

Battery clips

Dimensions/Weight:

5.31” x 3.15” x 1.73” (135 x 80 x 
44mm)/ 0.77 lbs. (350g)

Items manufactured by companies other than Smith-Root carry 

the original manufacturer’s warranty. Please contact product 

manufacturer for return instructions.

All Smith-Root, Inc. manufactured products are covered by a one year warranty.  

Credit & Refund Policy:  Customers returning equipment, in new condition, will 

be given credit five days from the date of the return. A return authorization 

must accompany returns. Valid equipment returns include, but are not limited 

to, ordering incorrect equipment, funding deficits, and defective equipment 

returned for reimbursement. All returns are subject to a restocking fee and 

applicable shipping charges. The restocking fee is figured at 10% of the 

purchase price but not less than $20.00. Customers receiving equipment in 

damaged condition will be referred to the shipping company for insurance 

reimbursement.

07292.13 UBC-24 Manual - © 2015 Smith-Root, Inc. 

BATTERY CYCLE LOG

Use this form* to record the number of times a 
battery has been cycled:

DATE:

SERIAL #:

NOTES:

BATTERY CYCLE LOG

Use this form to record the number of times a 
battery has been cycled:

DATE:

SERIAL #:

NOTES:

BATTERY CYCLE LOG

Use this form to record the number of times a 
battery has been cycled:

DATE:

SERIAL #:

NOTES:

STORAGE INSTRUCTIONS

•  When not in use, store the charger indoors in 

a cool dry place, preferably with its original 
packing and carton.

•  Place these instructions with the charger 

during storage.

MAINTENANCE AND CLEANING

•  Very little maintenance is required other than 

protecting the charger from damage and 
weather.

•  Coil cord when not in use.
•  Clean case and cords with a slightly damp 

cloth.

•  Examine cords for damage periodically and re-

place if necessary with manufacturer approved 
parts.

BAT-01 BATTERY ANALYSIS TOOL

The Battery Analysis 
Tool is an accessory 
designed to oper-
ate with existing 
Smith-Root batter-
ies and chargers. Its 
purpose is to test 
back-pack Electro-
fisher batteries, and 
to demonstrate in a 
clear concise manner 
the amount of usable life remaining in batteries 
being tested.

CHARGING OTHER SMITH-
ROOT BATTERIES

The UBC-24 Battery Charger is designed to 
charge batteries for LR-Series Electrofisher Sys-
tems. However, users that have an inventory of 
older-style Smith-Root electrofisher batteries can 
charge them with the following adapters:
The 

Model 12 Battery to LR-Series Charger 

Adapter

 (#07458) will allow you to charge Model 

12 Batteries (#03298 & #02595) with the current 
model of UBC-24.
The 

LR-Series Battery to Model 12 Adapter Ca-

ble

 (#07459) will allow you to charge LR-Series 

lead-acid batteries with our older, Model 12 style 
BC-24 Battery Charger (#04954) with a 4-pin 
connector.
The 

Lithium Battery Adapter Cable

  (#10791)  al-

lows charging of 9.6Ah Lithium batteries with the 
UBC. It is supplied with each Lithium battery but 
is also available separately.

BAT-01

UBC-24

From AC

Battery

Under

Test

Bat-01 Hookup

BAT-01 Battery Analysis Tool ......... #08041

Model 12 Battery to LR-Series Charger ..07458
LR-Series Battery to Model 12 Charger ..07459
Lithium Battery Cable .................................. 10791

7

8

9

10

Phone: (360) 573-0202 • Email: [email protected]

Vancouver, WA USA

12Ah 24V

 

The 12 Amp-hour battery provides 
extended electrofishing time as 
compared to a standard 7Ah 
battery.

Weight ..........14.75 lbs.
Part # ................ 06682

7Ah 24V 

Our 7 Amp-hour battery comes 
standard with the LR-20 and LR-24 
electrofishers combos and provides 
a good balance between weight and 
power.

Weight .............10.3 lbs.
Part # ..............06681

24V 9.6AH

Our lithium iron phosphate  battery 
is half the weight of our lead-acid 
batteries, with a much higher 
recharge capacity.
LITHIUM BATTERY ADAPTER 
(10791) is included with each battery 
purchased.

Weight .............5.95 lbs.
Part # .............. 10765

SMITH-ROOT BATTERIES

We currently offer two lead-acid batteries for SRI 
Backpack Electrofishers. Both are 24 volt, sealed deep 
discharge-rated, lead acid batteries. 
Also available is our new lightweight lithium-iron phos-
phate battery.

To learn more about batteries, visit: 

www.smith-root.com/electrofishers/batteries

 or consult 

the instruction sheet supplied with your Smith-Root 
battery.

*To preserve the integrity of your UBC-24 instruction sheet, photocopy and print out this section for your own use.

Summary of Contents for UBC-24

Page 1: ...07292 13 UBC 24 Man USER S GUIDE UBC 24 U N I V E R S A L B AT T E R Y C H A R G E R...

Page 2: ...IONAL INSTRUCTIONS 2 CHARGING 3 LEDS AND CHARGE STATUS 4 CONNECTORS AND INDICATORS 5 CHARGING LITHIUM BATTERIES 5 CHARGER OPERATING INSTRUCTIONS 6 STORAGE INSTRUCTIONS 7 MAINTENANCE AND CLEANING 7 CHA...

Page 3: ...r designed to charge lead acid and lithium batteries for the LR 24 LR 20 Series and earlier Smith Root 24V models electrofisher systems utilizing a three stage charging sequence O WARNING Explosive ga...

Page 4: ...ror occurs the plug should be immediately removed from the socket The charger contains dangerous voltages and the cover should not be removed All service or maintenance work should be carried out by q...

Page 5: ...ging is finished disconnect the charger from the wall socket then disconnect the battery Do not leave batteries on the char ger once fully charged BAT 01 In y er o nd es WARNING Explosive gases can ar...

Page 6: ...Standby Ready The charger is in standby mode The battery is fully charged The LED changes to green The charge voltage is at standby level which means the charger can continue to be connected to the b...

Page 7: ...sher batter ies with different terminal connec tors can charge them with the UBC 24 using adapter cables available from SRI See page 8 CHARGING SRI LITHIUM BATTERIES Use the adapter cable provided wit...

Page 8: ...its maximum Final charge The charger is in constant voltage mode Charge current is less than its maximum The battery is normally 80 95 charged The charger stays in this mode until the charge current...

Page 9: ...lightly damp cloth Examine cords for damage periodically and re place if necessary with manufacturer approved parts BAT 01 BATTERY ANALYSIS TOOL The Battery Analysis Tool is an accessory designed to o...

Page 10: ...e Model 12 Batteries 03298 02595 with the current model of UBC 24 The LR Series Battery to Model 12 Adapter Ca ble 07459 will allow you to charge LR Series lead acid batteries with our older Model 12...

Page 11: ...ot carry the original manufacturer s warranty Please contact product manufacturer for return instructions All Smith Root Inc manufactured products are covered by a one year warranty Credit Refund Poli...

Page 12: ...BATTERY CYCLE LOG Use this form to record the number of times a battery has been cycled DATE SERIAL NOTES B U b D 10...

Page 13: ...www smith root com Phone 360 573 0202 Email info smith root com Vancouver WA USA d y ult...

Reviews: