background image

 
 

Installation, operating and maintenance manual 

Vision MKII 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

Smeva BV 
 
Visiting address: 

J.F. Kennedylaan 27 

 

 

5555 XC Valkenswaard 

 
 
Telephone:  

 

+31 40 20 73 200 

Internet: 

 

www.smeva.com

 

 

 
 

Specifications for the manual: 

Date: December 2015 
Version: 1.0 
 

 

 

Summary of Contents for Vision MKII

Page 1: ...ating and maintenance manual Vision MKII Smeva BV Visiting address J F Kennedylaan 27 5555 XC Valkenswaard Telephone 31 40 20 73 200 Internet www smeva com Specifications for the manual Date December...

Page 2: ...ol panel Optional OEM control panel Optional ultrasonic humidifier Optional reverse osmosis filter Optional fish display case Optional micro misting Accessories Copyright This manual is a publication...

Page 3: ...on surface 6 Night cover 7 Discharge grille 8 Intake grille 9 Fan 10 Work surface 11 Product identification label 12 Cooled evaporator 13 Distribution pipe ultrasonic mister 14 Thermostat control and...

Page 4: ...bel holder 5 Cold plate presentation surface 6 Night cover 7 Discharge grille 8 Intake grille 9 Fan 10 Work surface 11 Product identification label 12 Cooled evaporator 13 Distribution pipe ultrasonic...

Page 5: ...ice card rail label holder 5 Cold plate presentation surface 6 Night cover 7 Discharge grille 8 Intake grille 9 Fan 10 Work surface 11 Product identification label 12 Cooled evaporator 13 Distribution...

Page 6: ...4 Price card rail label holder 5 Intake grille 6 Product stop 7 Cold shelf presentation surface 8 Night cover 9 Fan 10 Heater electric defroster 11 Discharge grille 12 Work surface 13 Product identifi...

Page 7: ...LIVERY COPYRIGHT 1 CONTENTS 6 EXTERNAL DOCUMENTS 7 SAFETY 8 1 INTRODUCTION 11 2 TRANSPORT INSTALLATION 12 3 GUIDELINES FOR USE 26 4 CLEANING MAINTENANCE 37 5 END OF LIFE DISASSEMBLY DISPOSAL 46 6 TROU...

Page 8: ...sion MKII 7 External documents External documentation Data sheet Electrical wiring diagram Refrigeration system diagram Floor plan Optional items The external documentation is available on request fro...

Page 9: ...result in situations that are hazardous to people and may cause damage to the product Failure to comply with the safety guidelines can lead to loss of the right to compensation for damages and may vo...

Page 10: ...e located on the serving side The electrical connection box and devices are located on the serving side behind the service panel Danger due to moving parts Fan present near the evaporator Danger of in...

Page 11: ...cleaned with soap and lots of water Never spray water on the electrical parts beyond this surface The control panels The mains sockets The fans The anti condensation nose fans hidden behind the nose p...

Page 12: ...is located behind the discharge grilles for the cooled air Optional ultrasonic humidifier for fresh products The water supply for the humidifier is filtered with a reverse osmosis filter Optional fis...

Page 13: ...ype of glass panels the glass is supported with wooden beams or the glass has been removed to prevent damage during transport The glass at the ends has also been removed Inspect all parts immediately...

Page 14: ...case must be done with lifting equipment that is carefully inserted between the wooden transport beams and beneath the steel profiles carefully balanced in the centre of the length and weight of the d...

Page 15: ...r the display case The wooden transport beam can be detached by removing a single screw from the serving side of the display case see figure and using a hammer carefully if the beam is stuck Phillips...

Page 16: ...2 Transport installation Vision MKII 15 Removing the front panels 1 Lift up the panel 2 Pull the panel toward you 3 Pull the panel down until the top side detaches...

Page 17: ...ubbles 3 Join the two display case sections together 4 Remove the excess caulk Use soapy water to form a smooth continuous caulk surface Apply the caulk before the display cases are joined together Th...

Page 18: ...s Vision Cube Assembly of joined display case sections Joining is accomplished with threaded rods in the frame 1 Align the aluminium nose profiles with round keys 2 Aligned Threaded rods and M8 bolts...

Page 19: ...rface with the two extending joining brackets pos 4 and screws pos 3 Aligned Joining bracket for stainless steel work surface 3 4 included Alignment of lighting profiles Align the aluminium lighting p...

Page 20: ...propriate keys Aligned Square or round bumper rail and bag bench holder keys included Stainless steel bag bench holder bolts included Connecting electrical wiring between display cases Electrical conn...

Page 21: ...a nationally certified authorized professional Connecting water supply between display cases if equipped with humidifier Water line connections are prepared under the display case 6 mm Connect the lin...

Page 22: ...located under the evaporator is connected by means of a plastic sleeve 32 mm Sleeve 32 mm included Connecting micro misting humidification system between display cases The distribution line for the op...

Page 23: ...consumer side see figure Use the plastic sealing profiles to prevent cleaning water from running under the display case 2 Phillips screwdriver Self tapping screws included Black colour for black skirt...

Page 24: ...ont panels KU PA Fitting of the panels is done in the opposite order of removal see Removing the front panels 1 Push the panel up behind the U profile 2 Push the bottom toward the display case 3 Caref...

Page 25: ...ate pressure 0 5 bar When opening observe whether the pipe is still under pressure If not contact your Smeva partner See the floor plan for the correct positions of the connections Diameter and coolin...

Page 26: ...lectrical connection is made by connecting the mains feed to the electrical terminal box in the frame cable gland size PG16 2 Power supply for mains sockets A separate terminal box in the frame All th...

Page 27: ...intended for presentation Do not fill above the fill level as indicated on the stickers on the glass side panels because doing so prevents the cooled air from effectively reaching the products Never...

Page 28: ...for fresh products with a non removable presentation surface Air circulation presentation surface Vision for packaged products with a removable presentation surface Lighting and draughts are a major...

Page 29: ...before you fill it with products The serve over display case is only intended for fresh products Make sure the presentation surface is filled correctly because this can affect the air circulation and...

Page 30: ...obstruct the openings in the air grilles at the front and rear Make sure the openings of the intake grille do not become blocked by products boards trays etc This can obstruct the air circulation whi...

Page 31: ...airflow Lighting LED lighting is mounted in the lighting profile Use only original LED lighting from SMEVA intended specifically for your products Ask your dealer for the available colours The light s...

Page 32: ...d air for packaged products Recommended defrosting cycles 4x 45 min 24 hrs Defrost stop 6 C cycle off Defrost stop 8 C electric defrosting Night cover When night covers or roller curtains are used the...

Page 33: ...ble hole to feed the plug and lead of the auxiliary equipment through 6 Pass the plug out through the hole in the mains socket rail in bottom Connect the plug of the auxiliary equipment to the nearest...

Page 34: ...tions during the night The products remain under covered dark conditions and it is not necessary to remove them from the display case Energy consumption during the night is reduced by 50 To prevent pr...

Page 35: ...are activated The device is set to 100 capacity at the factory Depending on the length of the display case up to max 4 375 m the setting can be reduced with the control knob which is located in the ma...

Page 36: ...e device is set at the factory to atomize for 2 3 seconds every 15 20 minutes The interval can be set with the adjustment knob on the front of the device which is accessible behind the service panel S...

Page 37: ...ed can lead to contamination with legionella bacteria which poses a danger to both the personnel and the public Contamination of the water can cause the humidification system to function poorly or bec...

Page 38: ...ized technician This inspection must include the following 1 Cleaning of condensation drains air ducts and the water drain system Timely repair of degraded or damaged materials or coatings and seals t...

Page 39: ...ve the display appliance unattended with the glass panel in the open position employees and customers might walk into it Cleaning Before cleaning the presentation surface always switch off the refrige...

Page 40: ...ed in the usual manner with a cloth and warm soapy water Aggressive cleaners may scratch the surface of the laminated sheet Exterior of the appliance anti fingerprint AFP stainless steel AFP stainless...

Page 41: ...an this wet stainless steel surface with warm water 50 C and soap and rinse with lots of clean water Free of contamination We recommend that the presentation surface and discharge and intake grilles b...

Page 42: ...teel work surface is subject to contamination with salt blood Clean this dry stainless steel surface regularly with lots of warm water Dry this surface carefully after cleaning Dry Do not use abrasive...

Page 43: ...lass must first be removed from the two clamps Use a Torx screwdriver to loosen the clamping block Torx screwdriver The following photos show how to remove a gas spring from the support Use a slotted...

Page 44: ...rows in the figure The top edge of the side window is attached to the light profile with a screw The adjustment screws can be turned with a large screwdriver or a coin making it possible to adjust the...

Page 45: ...the stops in the hinge profiles This is done by loosening the socket head screws several turns Allen wrench 3 mm Correct left right position Gap between glass panels 2 6 mm Height adjustment Adjust t...

Page 46: ...ound plastic profile 2 Set the adjustment screw to the correct position Profile in out to desired position Small slotted screwdriver 3 Place the round plastic profile back into the aluminium profile C...

Page 47: ...f the display case In terms of recycling or the reuse of parts at the end of the service life specific parts can be used again in a second life cycle Contact your Smeva dealer for the responsible sust...

Page 48: ...it to which the Vision display case is connected Fuse OK or circuit breaker on Residual current device on If you cannot find the cause contact your Smeva partner Partial malfunction If the Vision is o...

Page 49: ...ized steel Polyurethane foam Anodized aluminium Power coated steel and galvanized profiles with adjustable feet Polyurethane parts fabricated without the use of greenhouse and ozone depleting gases El...

Page 50: ...have questions or in the event of a malfunction the left compartment on the serving side of your Vision display case contains the machine stickers shown below Copy this information and provide it to...