3 Putting into operation 

The refrigerated service cabinet can be put into operation after installation by an authorised 
refrigeration contractor, see Chapter 2. For the proper functioning of the refrigerated service 
cabinet take the following instructions into account. 

 

External influences 

 

Avoid direct sunlight. Excessive sunlight can 
have a negative effect on the performance of 
the refrigerated service cabinet. 

 

Keep heat sources out of the vicinity of the 
refrigerated service cabinet. (Examples are: 
radiators, ovens, spot lights, air curtains) 

 

Take into consideration that the appliance 
was not designed for cooling goods, but for 
storing cooled goods. 

 

Only packaged or properly wrapped goods 
may be stored in the refrigerated service 
cabinet. Do not store opened packages or 
fresh products without wrapping them.  

 

Stack the goods in the compartments leaving 
enough space for ventilation. For sufficient 
cool circulation never completely block the 
space between the compartments with 
stacked goods. 

 

Close the doors after use and never leave 
them open unnecessarily.

 

 

Summary of Contents for SC C3

Page 1: ...manual Refrigerated service cabinet Smeva BV Address J F Kennedylaan 27 5555 XC Valkenswaard Telephone 040 2073200 Internet www smeva nl Production date June 2011 Specifications of the manual Date Aug...

Page 2: ...ors The appliance was designed for deep reach in other words it is not suitable for freezing products Cool circuit with evaporative cooler for connection of a remote cooling unit Controlling for tempe...

Page 3: ...PYRIGHT 2 SAFETY 4 APPLIANCE SPECIFICATIONS 6 1 INTRODUCTION 9 2 INSTALLATION 10 3 PUTTING INTO OPERATION 13 4 THERMOSTAT CONTROL 15 5 CLEANING 17 6 GENERAL MAINTENANCE 20 7 TERMINATION OF USE DISASSE...

Page 4: ...f contract regarding damage remuneration and guarantee More specifically not observing the safety guidelines can lead to the following damages loss of important functions of the product hazard to peop...

Page 5: ...s a lift truck forklift crane etc Use suitable equipment for this purpose People carrying out these activities should wear personal safety equipment gloves protective glasses shoes etc and should not...

Page 6: ...mpartments per door model height 867 mm excl countertop Independent appliance units 1000 1500 2000 2500 and 3000 mm Inside RVS Exterior PVC laminated plate or RVS anti fingerprint RVS AFP Dimensions o...

Page 7: ...e digital thermostat using a control These options are also available a set of valves in the coolant piping with which the refrigerator can be manually closed for repairs a filter in the coolant pipin...

Page 8: ...Refrigerated service cabinet v 1 0 8 Electrical specifications...

Page 9: ...igeration company The coolant piping condensation drain and the electrical connection are located under the appliance The refrigerated service cabinet meets the requirements for being of the highest q...

Page 10: ...to it on site The refrigerated service cabinet should be placed on a level surface Horizontal Level Adjustable feet Any potential instability caused by play underneath one or more of the adjustable fe...

Page 11: ...ing face Place both appliance units next to each other Equal height Level Insert M8 threaded ends through the feet Draw the appliance units towards each other by fastening the threaded ends with nuts...

Page 12: ...pe plate Electrical connections should be executed in accordance with the applicable regulations Before any repair work is carried out on the electrical live parts the power supply to the part involve...

Page 13: ...et Keep heat sources out of the vicinity of the refrigerated service cabinet Examples are radiators ovens spot lights air curtains Take into consideration that the appliance was not designed for cooli...

Page 14: ...rection that the doors open is determined beforehand and delivered as such from the factory If the direction of the door opening must be altered contact your Smeva dealer Door handles Always open the...

Page 15: ...nder the second door from the left behind the transport girder The standard setting of the set point is 0 C Remove the left skirting board and the outer skirting board by loosening the screws Transpor...

Page 16: ...y 24 hours Depending on the use and the frequency of the doors opening an additional defrost cycle might need to be scheduled on the thermostat regulator The manual defrost function operates via the t...

Page 17: ...ater Then dry the appliance Never use aggressive cleaners Only use cleaners with a pH degree of acid from 4 to 9 When working on the interior of the appliance one should be aware of potential electric...

Page 18: ...stains For more severe dirt or stains on RVS AFP see below for further instructions Cleaning RVS AFP severely dirty surface or stubborn stains For stubborn residuals use a non abrasive multifunctional...

Page 19: ...and the door plate thoroughly Dirt can accumulate and fungus develops Evaporative coolers Clean the exterior of the evaporative coolers with a cloth and warm soapy water Free of dirt Defrosted Do not...

Page 20: ...n system cleaning and inspection of the drainage system Consult with your Smeva dealer about these maintenance schemes Magnetic rubber door sealers The magnetic rubber sealers should be replaced when...

Page 21: ...Damages caused by third parties are not covered by the guarantee A few parts are subject to wear and should be replaced during the life expectancy of the appliance When disposing of the refrigerated...

Page 22: ...efrigeration contractor if you are unable to resolve the problem Partial malfunction If the refrigerated service cabinet only functions partially and you cannot repair this by switching the appliance...

Page 23: ...laminated block in coated steel housing Steel with a cataphoresis coating and galvanized steel support systems Galvanized steel plastic adjustable feet RVS compartment frames with polypropylene crates...

Reviews: