-17-
6.6
CLEANING SOLENOID VALVE FILTER / SOLENOID VALVE REPLACEMENT
Close the inlet water valve.
1
2
3
4
4
Remove the pressure in the feed pipe, making the
machine run for 10 seconds.
Turn off the machine and remove the ¾” fitting from
the solenoid valve.
Using pliers, gently pull the solenoid valve filter.
Clean the filter with tap water and/or compressed air.
Item:
1. Solenoid valve
2. Mesh filter
3. Solenoid valve bracket
4. Screws
If solenoid valve is damaged, and every 2000 hours of working time, replace them with a new one.
To remove the solenoid valve:
1. disconnect the internal fittings,
2. disconnect the power cables from the electric terminal board
3. unscrew the two fixing screws
4. remove the solenoid valve and the bracket
5. install the new solenoid valve with reverse procedure.