Smeg Victoria SR975BGH Manual Download Page 4

General instructions

28

2. SAFETY PRECAUTIONS

REFER TO THE INSTALLATION INSTRUCTIONS FOR THE SAFETY REGULATIONS
FOR ELECTRIC OR GAS APPLIANCES AND VENTILATION FUNCTIONS.
IN YOUR INTERESTS AND FOR YOUR SAFETY IT HAS BEEN ESTABLISHED BY LAW

THAT THE INSTALLATION AND SERVICING OF ALL ELECTRICAL APPLIANCES IS TO

BE CARRIED OUT BY QUALIFIED PERSONNEL IN ACCORDANCE WITH THE
REGULATIONS IN FORCE.
OUR APPROVED INSTALLERS GUARANTEE A SATISFACTORY JOB.
GAS OR ELECTRICAL APPLIANCES MUST ALWAYS BE DISCONNECTED BY
SUITABLY SKILLED PEOPLE.

BEFORE CONNECTING THE APPLIANCE TO THE POWER GRID, CHECK THE DATA
ON THE PLATE AGAINST THE DATA FOR THE GRID ITSELF.

THE IDENTIFICATION PLATE CONTAINING THE TECHNICAL DATA, SERIAL NUMBER

AND BRAND NAME IS IN A VISIBLE POSITION UNDER THE CASING.

DO NOT REMOVE THE PLATE ON THE CASING FOR ANY REASON.

BEFORE CONNECTING THE APPLIANCE, ENSURE THAT IT IS SET TO THE TYPE OF
GAS THAT IT WILL BE SUPPLIED WITH, CHECKING THE LABEL APPLIED UNDER

THE CASING.

BEFORE CARRYING OUT INSTALLATION/MAINTENANCE WORK, MAKE SURE THAT

THE APPLIANCE IS NOT CONNECTED TO THE POWER GRID.

THE PLUG TO BE CONNECTED TO THE POWER SUPPLY CABLE AND ITS SOCKET

MUST BE OF THE SAME TYPE AND CONFORM TO THE REGULATIONS IN FORCE.

THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN BUILT IN.

NEVER DISCONNECT THE PLUG BY PULLING ON THE CABLE.

IF THE POWER SUPPLY CABLE IS DAMAGED, CONTACT THE TECHNICAL SUPPORT
SERVICE IMMEDIATELY AND THEY WILL REPLACE IT.

THE APPLIANCE MUST BE CONNECTED TO EARTH IN COMPLIANCE WITH

ELECTRICAL SYSTEM SAFETY REGULATIONS.

IMMEDIATELY AFTER INSTALLATION, CARRY OUT A BRIEF INSPECTION TEST,
FOLLOWING THE

INSTRUCTIONS

BELOW.

SHOULD THE

APPLIANCE

NOT

FUNCTION, DISCONNECT IT FROM THE POWER SUPPLY AND CALL THE NEAREST

TECHNICAL SUPPORT CENTRE.

NEVER ATTEMPT TO REPAIR THE APPLIANCE.

DURING USE THE APPLIANCE BECOMES VERY HOT. TAKE CARE NOT TO TOUCH

THE HEATING ELEMENTS.

THE USE OF THIS APPLIANCE IS NOT PERMITTED TO PEOPLE (INCLUDING

CHILDREN) OF REDUCED PHYSICAL AND MENTAL ABILITY, OR LACKING IN
EXPERIENCE IN THE USE OF ELECTRICAL APPLIANCES, UNLESS THEY ARE
SUPERVISED OR INSTRUCTED BY ADULTS OR PEOPLE RESPONSIBLE FOR THEIR
SAFETY.

Summary of Contents for Victoria SR975BGH

Page 1: ...eaning and maintenance of the appliance INSTRUCTIONS FOR THE INSTALLER these are intended for the qualified technician who must install the appliance set it functioning and carry out an inspection tes...

Page 2: ...OTHER THAN AS INDICATED IF THE APPLIANCE IS INSTALLED ON BOATS OR IN CARAVANS DO NOT USE IT AS A ROOM HEATER DO NOT USE THIS APPLIANCE FOR HEATING ROOMS THIS APPLIANCE IS MARKED ACCORDING TO EUROPEAN...

Page 3: ...AT THE CONTROL KNOBS ARE IN THE OFF POSITION WHEN YOU FINISH USING THE HOB NEVER PLACE PANS WITH BOTTOMS WHICH ARE NOT PERFECTLY FLAT AND SMOOTH ON THE COOKING HOB RACKS NEVER USE CONTAINERS WHICH PRO...

Page 4: ...FORE CARRYING OUT INSTALLATION MAINTENANCE WORK MAKE SURE THAT THE APPLIANCE IS NOT CONNECTED TO THE POWER GRID THE PLUG TO BE CONNECTED TO THE POWER SUPPLY CABLE AND ITS SOCKET MUST BE OF THE SAME TY...

Page 5: ...COULD REACH THE ELECTRONICS DAMAGING THEM AND CAUSING SHORT CIRCUITS DO NOT MODIFY THIS APPLIANCE DO NOT SPRAY ANY SPRAY PRODUCTS NEAR THE ELECTRICAL APPLIANCE WHILE IT IS IN OPERATION DO NOT USE SPR...

Page 6: ...r results in the application of administrative sanctions The product does not contain substances in quantities sufficient to be considered hazardous to health and the environment in accordance with cu...

Page 7: ...mum flame symbol until it lights On valved models hold down the knob for about 2 seconds to keep the flame lit and to activate the safety device The burner may go out when the knob is released If this...

Page 8: ...1 Auxiliary 7 18 2 Semi rapid 10 24 3 Medium Rapid 12 24 4 Large Rapid 14 26 5 Double crown ultra rapid 12 28 6 Triple crown ultra rapid 22 28 7 Fish burner Suitable oval containers For burner referen...

Page 9: ...ry daily cleaning To clean and preserve surfaces always use only specific products that do not contain abrasives or chlorine based acids How to use pour the product onto a damp cloth and wipe the surf...

Page 10: ...ese components must not be washed in the dishwasher 5 2 3 Flame spreader crowns The flame spreader crowns are removable Wash them with hot water and non abrasive detergent making sure to remove any en...

Page 11: ...he cooktop remove the lid unit by lifting it upwards When finished cleaning refit the cover making sure to insert it correctly Before lifting up the lid dry out any liquid that may have dripped Never...

Page 12: ...e counte A mm B mm C mm D mm E mm L mm X mm Y mm min 145 min 460 min 750 20 40 min 50 690 555 560 478 482 Carefully position the supplied insulating seal on the outer perimeter of the hole made in the...

Page 13: ...an empty kitchen unit with doors a separation panel must be placed under the hob Keep a minimum distance of 10 mm between the bottom of the hob and the surface of the panel which must be easily extrac...

Page 14: ...equal to or greater than 3 mm in an easily accessible position close to the appliance Avoid use of adapters and shunts If the power cable is replaced the cross section of wires in the new cable must b...

Page 15: ...eset for natural gas G20 2H at a pressure of 20 mbar For supplying it with other types of gas see chapter 9 ADAPTATION TO DIFFERENT TYPES OF GAS The gas inlet connection is threaded for external gas I...

Page 16: ...protected by grills must be the right size to comply with current regulations and positioned so that no part of them is obstructed not even partially The room must be kept adequately ventilated in ord...

Page 17: ...e replaced and the primary air must be adjusted In order to replace the nozzles and adjust the burners the hob top must be removed as described below 9 1 Removing the hob top 1 Remove all the knobs pa...

Page 18: ...5 Primary air adjustment and then secure the tube by means of screw A After the adjustments have been carried out restore the seals with sealing wax or equivalent material Burner Rated heating capaci...

Page 19: ...0 The values for city gas refer to appliances in category III 1a2H3 9 4 Adjustment for natural gas The hob is preset for natural gas G20 2H at a pressure of 20 mbar To reset the appliance for operatio...

Page 20: ...hob 9 6 Final operations After making the adjustments described above reassemble the appliance by following the instructions in 9 1 Removing the hob top in reverse order 9 6 1 Adjusting the minimum fo...

Page 21: ...e tap rod depending on the model fully in a clockwise direction The bypass diameters for each individual burner are shown in table 9 2 Adjustment for LPG After adjustment with a gas other than the pre...

Page 22: ...id 5 Triple crown ultra rapid 6 Double crown ultra rapid 7 Fish burner 9 8 Lubrication of gas taps Over time the gas taps may become difficult to turn and get blocked Clean them internally and replace...

Reviews: