Problem
Possible cause
Solution
The compressor does not
start immediately after
pressing the "IntensiveCool‐
ing", or after changing the
temperature.
This is normal, no error
has occurred.
The compressor starts after a
period of time.
Water flows inside the refrig‐
erator.
Food products prevent the
water to flow into the wa‐
ter collector.
Make sure that food products
do not touch the rear plate.
The water outlet is clog‐
ged.
Clean the water outlet.
Water flows on the floor.
The melting water outlet is
not connected to the evap‐
orative tray above the
compressor.
Attach the melting water outlet
to the evaporative tray.
Temperature cannot be set.
The "IntensiveCooling
function" is switched on.
Switch off "IntensiveCooling
function" manually, or wait un‐
til the function resets automati‐
cally to set the temperature.
Refer to "IntensiveCooling
function".
The temperature in the ap‐
pliance is too low/too high.
The temperature regulator
is not set correctly.
Set a higher/lower tempera‐
ture.
The door is not closed cor‐
rectly.
Refer to "Closing the door".
The food products' tem‐
perature is too high.
Let the food products temper‐
ature decrease to room tem‐
perature before storage.
Many food products are
stored at the same time.
Store less food products at the
same time.
The door has been
opened often.
Open the door only if necessa‐
ry.
The "IntensiveCooling
function" is switched on.
Refer to "IntensiveCooling
function".
There is no cold air circu‐
lation in the appliance.
Make sure that there is cold
air circulation in the appliance.
If the advice does not lead to
the desired result, contact the
nearest Authorised Service
Centre.
Replacing the lamp
The appliance is equipped with a longlife
LED interior light.
10