3. Connect the wire coloured brown to
the terminal either marked with the
“L“ or coloured red.
4. Check that no cut, or stray strands of
wire is present and the cord clamp (E)
is secure over the outer sheath.
Make sure the electricity supply
voltage is the same as that indicated
on the appliance rating plate.
5. Switch on the appliance.
The appliance is supplied with a 13 amp
fuse (B). In the event of having to change
the fuse in the plug supplied, a 13 amp
ASTA approved (BS 1362) fuse must be
used.
WARNING! A cut off plug
inserted into a 13 amp socket
is a serious safety (shock)
hazard. Ensure that it is
disposed of safely.
Ventilation requirements
The airflow behind the appliance must be
sufficient.
5 cm
min.
200 cm
2
min.
200 cm
2
CAUTION! Refer to the
assembly instructions for the
installation.
TECHNICAL DATA
Technical data
Dimensions of the recess
Height
mm
1780
Width
mm
560
Depth
mm
550
Rising time
Hours
16
Voltage
Volts
230 - 240
Frequency
Hz
50
The technical information is situated in the
rating plate, on the external or internal
side of the appliance and in the energy
label.
ENVIRONMENTAL CONCERNS
Recycle materials with the symbol . Put
the packaging in relevant containers to
recycle it. Help protect the environment
and human health by recycling waste of
electrical and electronic appliances. Do
13