Installation
37
EN
Burner and nozzle characteristics tables
1 Natural Gas G20
AUX
SR
R
UR2 int.
UR2
Rated heating capacity (kW)
1.0
1.8
3.0
0.9
4.2
Nozzle diameter (1/100 mm)
72
97
115
70
97+97
Pre-chamber (printed on nozzle)
(X)
(Z)
(Y)
(X)
(Z)
Reduced capacity (W)
400
500
800
400
1600
2 Natural Gas G25
AUX
SR
R
UR2 int.
UR2
Rated heating capacity (kW)
-
-
-
-
-
Nozzle diameter (1/100 mm)
-
-
-
-
-
Reduced capacity (W)
-
-
-
-
-
3 Natural Gas G25
AUX
SR
R
UR2 int.
UR2
Rated heating capacity (kW)
-
-
-
-
-
Nozzle diameter (1/100 mm)
-
-
-
-
-
Reduced capacity (W)
-
-
-
-
-
4 Liquid Gas G30/31
AUX
SR
R
UR2 int.
UR2
Rated heating capacity (kW)
1.0
1.8
3.0
0.9
4.2
Nozzle diameter (1/100 mm)
50
65
85
46
65+65
Reduced capacity (W)
400
500
800
400
1600
Rated capacity G30 (g/h)
76
131
218
65
305
Rated capacity G31 (g/h)
75
129
215
64
300
5 Liquid Gas G30/31
AUX
SR
R
UR2 int.
UR2
Rated heating capacity (kW)
-
-
-
-
-
Nozzle diameter (1/100 mm)
-
-
-
-
-
Pre-chamber (printed on nozzle)
-
-
-
-
-
Reduced capacity (W)
-
-
-
-
-
Rated capacity G30 (g/h)
-
-
-
-
-
Rated capacity G31 (g/h)
-
-
-
-
-
6 City Gas G110
AUX
SR
R
UR2 int.
UR2
Rated heating capacity (kW)
-
-
-
-
-
Nozzle diameter (1/100 mm)
-
-
-
-
-
Reduced capacity (W)
-
-
-
-
-
7 City Gas G120
AUX
SR
R
UR2 int.
UR2
Rated heating capacity (kW)
-
-
-
-
-
Nozzle diameter (1/100 mm)
-
-
-
-
-