Instructions for the installer
20
9.2
Adjustment for LPG
Loosen screw
A
and push support
B
all the way. Using a a double head, remove
nozzle
C
and replace it with the appropriate nozzle, following the instructions in
the tables for the type of gas to be used. The nozzle tightening torque must be
no more than
3 Nm
. Reposition support
B
so that nozzle
C
is covered perfectly.
Move the Venturi tube
D
to adjust the air flow until distance “
X
” is reached
indicated in the chart in paragraph "5.5 Primary air adjustment” and then secure
the tube by means of screw
A
. After the adjustments have been carried out,
restore the seals with sealing wax or equivalent material.
Burner
Rated
heating
capacity
(kW)
LPG – G30/G31
50 mbar
Nozzle
diameter
1/100 mm
Bypass
mm
1/100
Reduced
capacity
(W)
Capacity
g/h G30
Capacity
g/h G31
Auxiliary (1)
1.05
42
26
380
76
75
Semi-rapid (2)
1.65
54
26
380
120
118
Medium rapid (3)
2.55
67
33
650
185
182
Large Rapid (4)
3.1
73
37
750
225
222
Ultra-rapid (5)
3.3
76
52
1400
240
236
Double crown
Internal (6)
1.05
42
26
380
76
75
External (6)
3.9
82
53
1400
284
279
Fish burner (7)
2.0
60
37
750
145
143