Instructions for the installer
22
9.3
Adjustment for natural gas
The hob is preset for
natural gas
G20/G25
(2E+)
- G25 (2L 3B/P)
at a pressure of 20/25 mbar
- 25 mbar
. To reset the appliance for
operation with this type of gas, carry out the same steps as described in “9.2
Adjustment for LPG”, but select the nozzles and adjust the primary air for natural
gas as indicated in the table below and in “9.4 Primary air adjustment”.
After the adjustments have been carried out, restore the seals with sealing wax
or equivalent material.
Burner
Rated
heating
capacity
(kW)
Natural gas – G20/25
20/25 mbar
Nozzle diameter
1/100 mm
Reduced capacity
(W)
Auxiliary (1)
1.05
73
420
Semi-rapid (2)
1.65
92
480
Rapid (3)
3.1
126
750
Ultra-rapid (4)
3.3
130
1200
Double crown
internal (5)
1.05
73
380
external (5)
3.9
140
1200
Fish burner (6)
2.9
123
800
Burner
Rated
heating
capacity
(kW)
Natural gas – G25
25 mbar
Nozzle diameter
1/100 mm
Reduced capacity
(W)
Auxiliary (1)
1.05
76
380
Semi-rapid (2)
1.65
98
380
Rapid (3)
3.1
130
750
Ultra-rapid (4)
3.3
135
1200
Double crown
internal (5)
1.05
76
380
external (5)
3.9
150
1200
Fish burner (6)
2.9
126
800
BE
NL
BE
NL