Smeg SNZ60EVX Instructions For Installation And Use Manual Download Page 16

Instructions for the user

18

14.2 Gas connection

This appliance is suitable for installation with Natural Gas or LPG (propane).
Refer to page 12 for the relevant burner pressure and appropriate injector sizes.
When the appliance is to be connected to Natural Gas then the pressure regulator
supplied must be fitted to the gas inlet. A test point (for checking the gas
pressure) is supplied either with the regulator or as a separate fitting in the case
of LPG (propane) appliances.
Connection of the appliance to the gas supply must be in accordance with the
requirements of AS5601. A ½” BSP connector at the inlet is recommended and
the gas supply line to the appliance must be of adequate length to allow sufficient
withdrawal of appliance for service or disconnection and be annealed copper
pipe.
The cooker must be installed with provision to allow the gas to be turned off and
disconnected for servicing and removal of the appliance as required from the gas
supply. 
Before the cooker is operated make certain all relevant parts are placed in the
correct position.

When the installation is completed the installation connections of cooker will require to be leak tested,
the burner operating pressure and flame checked and adjusted.
Warranty service calls do not cover these adjustments!
To check the operating pressure of the appliance it is recommended at least 2 large size burners are
used. Ensure appliance is secured to wall when installation is completed.
N.G. The regulator supplied must be fitted to the ½ BSP thread at the rear of the appliance. An approved
manual shut-off valve must be installed. The N.G. regulator must be checked and adjusted to 1.0 kPa
after installation.

L.P.G. 

Can be connected to the inlet fitting directly. The pressure must be

checked to ensure it is operating at 2.75 kPa. A separate test point fitting must be
installed between the piping & the appliance for the pressure to be checked to
ensure it is operating at 2.75 kPa.

14.3 Room ventilation

Caution –

 This cooker may only be installed and operated in rooms permanently ventilated in

accordance with current regulations. For proper operation of a gas appliance it is essential for the air
necessary for combustion of the gas to be able to flow naturally into the room. Air must flow directly into
the room through openings in its outside walls.

This (these) opening (s) must have a free passage cross-section of at least 100 cm 

2

, or 200 cm 2 for

appliances not equipped with gas safety device. These openings must be constructed so that they
cannot be obstructed indoors or outdoors, and should preferably be close to the floor on the side
opposite to the combustion gas discharge point. If it is not possible to make the openings in the room
where the cooker is installed, the necessary air may be taken from an adjoining room, proveded it is not
a bedroom or a room with fire risk.

14.4 Clearance above and around domestic cookers

Summary of Contents for SNZ60EVX

Page 1: ...ON OF THE APPLIANCE 17 15 ADAPTATION TO DIFFERENT TYPES OF GAS 20 16 FINAL OPERATIONS 21 Thank you for choosing our product We advise you to read this manual carefully It contains all necessary instru...

Page 2: ...E THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN DIRECTIVE 2002 96 EC ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT WEEE THIS GUIDELINE IS THE FRAME OF A EUROPEAN WIDE VALIDITY OF RETURN AND RECYCL...

Page 3: ...children Your old appliance must also be disposed of properly Important deliver the appliance to your local organisation authorised to collect scrapped appliances Proper disposal allows the intelligen...

Page 4: ...ECT IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE NEVER ATTEMPT TO REPAIR THE APPLIANCE DO NOT PUT PANS WITHOUT PERFECTLY SMOOTH AND FLAT BOTTOMS ON THE HOB GRIDS DO NOT USE CONT...

Page 5: ...he nearest special garbage collection centre The inside of the appliance should be cleaned to remove all manufacturing residues For further information about cleaning see section 11 CLEANING AND MAINT...

Page 6: ...y heated Repeat the operation holding down the knob a little longer This operation is not necessary for burners without thermocouples For models with thermocouples should the burner accidentally go ou...

Page 7: ...ection of cooking temperature is carried out by turning the knob clockwise to the required temperature between 50 and 260 C If the appliance has an electric oven the warning light will come on when th...

Page 8: ...been turned on Fans cause a steady outflow of air from above the door which may continue for a brief period of time even after the oven has been turned off 9 3 Use of the electric grill For short cook...

Page 9: ...l is used the glass cover must always be up During and after use the accessible parts of the oven may be very hot and children must always be kept at a distance During cooking with the rotisserie one...

Page 10: ...hts Oven grill for cooking food on plates small cakes roasts or food requiring light grilling Plate grill for placing above plate for cooking foods that might drip Oven plate useful for catching fat f...

Page 11: ...move the grids and clean them in warm water with a non abrasive detergent taking care to remove any encrustations Replace them on the hob Continuous contact of the grids with the flame can cause the e...

Page 12: ...ow residues of sugary foods such as jam to set inside the oven If left to set for too long they might damage the enamel lining of the oven 11 6 Door glass The door glass should always be kept clean Us...

Page 13: ...n should be carried out by a specialised technician 12 2 Replacement of light bulb Remove cover A by twisting anticlockwise replace bulb B with another similar bulb 25 W Refit the cover A Only use ove...

Page 14: ...on the surface resulting in leakage of heat from the oven and higher temperatures on the control panel and knobs Check it periodically once a year and replace it if necessary Each of the following cas...

Page 15: ...two pole cut off device with contact cut off distance greater than or equal to 3 mm located in an easily accessible position near the unit The wire section on the cable must not be less than 2 5 mm 2...

Page 16: ...t least 2 large size burners are used Ensure appliance is secured to wall when installation is completed N G The regulator supplied must be fitted to the BSP thread at the rear of the appliance An app...

Page 17: ...lause 5 12 1 2 to a height C of not less than 150 mm above the hob for the full dimension width or depth of the cooking surface area Where the cooking appliance is fitted with a splashback protection...

Page 18: ...2 B 168 2 Attach the chain to the cooker 3 Stretch out the chain attached to the cooker horizontally so that the other end touches the wall 4 Mark the wall in the position where the hole is to be dril...

Page 19: ...t the minimum flame on the gas taps For nozzle replacement and burner adjustment operate as described in the following paragraph 15 1 Replacement of nozzles on the hob This operation requires no prima...

Page 20: ...TION MJ H INJECTOR MM Auxiliary 3 9 1 5 0 54 Semi rapid 6 3 1 5 0 68 WOK 12 8 5 4 1 00 Burner NG 1 0 KPA NOMINAL GAS CONSUMPTION MJ H TURN DOWN GAS CONSUMPTION MJ H INJECTOR MM Auxiliary 3 9 1 5 0 90...

Page 21: ...n place and check the stability of the burner flame the flame must not go out when the knob is turned quickly from the maximum to the minimum setting Repeat the operation on all the gas taps For model...

Page 22: ...914772495 E...

Reviews: