Adjustment
for natural gas
The hob has been adjusted for natural gas at a pressure of 1.0kPa.
To allow the unit to work back with this type of gas, after it has been
adjusted for ULPG, perform the same operations described in
paragraph “5.3 Adjustment for ULPG”, but refer to the following table
for the proper injectors.
NG – 1.0 kPa
Burner
Nominal gas
Consumption
(MJ/h)
Injector
(mm)
Auxiliary
4.8
0.98
Semi-rapid
5.9
1.10
Rapid
8.6
1.25
Rapid large
11.4
1.50
Fish pan
11.4
1.50
Wok
15
1.70