![Smeg SNLK916MFN9 Manual Download Page 41](http://html1.mh-extra.com/html/smeg/snlk916mfn9/snlk916mfn9_manual_1303691041.webp)
Installation
91
EN
Burner and nozzle characteristics tables
The nozzles not provided are available at Authorised Service Centres.
Natural Gas G20 - 20 mbar
AUX
SR
R
UR-3c
Rated heating capacity (kW)
1.05
1.8
3.0
3.5
Nozzle diameter (1/100 mm)
72
97
115
133
Pre-chamber (printed on nozzle)
(X)
(Z)
(Y)
(S)
Reduced flow rate (W)
400
500
800
1600
Natural Gas G25 - 25 mbar / G25.3 - 25 mbar
AUX
SR
R
UR-3c
Rated heating capacity (kW)
1.05
1.8
3.0
3.5
Nozzle diameter (1/100 mm)
72
94
121
138
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F2)
(F3)
Reduced flow rate (W)
400
500
800
1600
LPG G30/31 - 30/30 mbar
AUX
SR
R
UR-3c
Rated heating capacity (kW)
1.05
1.8
3.0
3.5
Nozzle diameter (1/100 mm)
50
65
85
94
Pre-chamber (printed on nozzle)
-
-
-
-
Reduced flow rate (W)
400
500
800
1600
Rated flow rate G30 (g/h)
76
131
218
255
Rated flow rate G31 (g/h)
75
129
214
250
Appliance set for:
G+ Groningen Group K gas
G25 (2L) - 25 mbar
G25.3 (2K) - 25 mbar