Instructions for the installer
26
3.2 Regulation for LPG
Loosen
screw
A
and
push
air
regulator B to the bottom.
With a 7 mm wrench, remove nozzle
C and replace it with the proper one
(follow
the
instructions
on
the
reference tables for the type of gas
to be used).
The torque wrench setting of the
nozzle must not exceed 3 Nm.
Regulate the air by sliding regulator
B until reaching distance “X” shown
in
the
table
in
paragraph
“3.4
Regulation of primary air”.
Lock
regulator
B
by
tightening
screw A.
Burner
Rated
heating
capacity
(kW)
LPG – G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Top with front controls:
Auxiliary
1.05
48
33
420
76
75
Semi rapid
1.65
62
33
420
120
118
Rapid
2.55
75
50
900
185
182
Ultrarapid
3.25
85
68
1500
236
232
Top with side controls:
Auxiliary
1.05
48
33
450
76
75
Semi rapid
1.65
62
33
450
120
118
Rapid
2.55
75
45
800
185
182
Ultrarapid
3.25
85
65
1500
236
232