background image

6

Safety Precautions

3. SAFETY PRECAUTIONS

SEE INSTALLATION INSTRUCTIONS FOR SAFETY REGULATIONS FOR
ELECTRIC OR GAS APPLIANCES AND FOR VENTILATION FUNCTIONS.
IN YOUR INTEREST AND TO ENSURE YOUR SAFETY, BY LAW ALL ELECTRIC
APPLIANCES MUST ONLY BE INSTALLED AND SERVICED BY QUALIFIED
STAFF, IN ACCORDANCE WITH THE RELEVANT REGULATIONS.
OUR APPROVED INSTALLATION ENGINEERS GUARANTEE YOU A JOB WELL
DONE.
GAS OR ELECTRIC APPLIANCES MUST ALWAYS BE DISCONNECTED BY
SUITABLY SKILLED PEOPLE.

THE PLUG TO BE CONNECTED TO THE POWER SUPPLY LEAD AND THE
RELATIVE SOCKET MUST BE OF THE SAME TYPE AND COMPLY WITH THE
RELEVANT REGULATIONS.
THE POWER SUPPLY SOCKET MUST BE ACCESSIBLE EVEN AFTER THE
APPLIANCE HAS BEEN BUILT-IN.

NEVER DISCONNECT THE PLUG BY PULLING ON THE POWER SUPPLY
LEAD

.

THE APPLIANCE MUST BE CONNECTED TO EARTH IN COMPLIANCE WITH
ELECTRICAL SYSTEM SAFETY REGULATIONS.

IMMEDIATELY AFTER INSTALLATION, CARRY OUT A QUICK TEST ON THE
APPLIANCE FOLLOWING THE INSTRUCTIONS PROVIDED LATER IN THIS
MANUAL. IF THE APPLIANCE FAILS TO OPERATE, DISCONNECT IT FROM
THE ELECTRICAL MAINS AND CONTACT YOUR NEAREST SERVICE CENTRE. 

NEVER ATTEMPT TO REPAIR THE APPLIANCE.

THE APPLIANCE BECOMES VERY HOT DURING USE. OVEN GLOVES
SHOULD ALWAYS BE WORN.

THE APPLIANCE IS INTENDED FOR USE BY ADULTS

. KEEP CHILDREN AT A

SAFE DISTANCE AND NEVER ALLOW THEM TO PLAY WITH IT.

AFTER EACH USE, ALWAYS CHECK THAT THE CONTROL KNOBS ARE
TURNED TO 0 (OFF).

The manufacturer declines all responsibility for injury or damage caused
by failure to comply with the above regulations or deriving from tampering
with even just one part of the appliance and the use of non-original spare
parts.

Summary of Contents for SNL900XGF

Page 1: ...intended for the qualified engineer who is to install commission and test the appliance 1 PRECAUTIONS FOR USE 4 2 DISPOSAL INSTRUCTIONS OUR ENVIRONMENT POLICY 5 3 SAFETY PRECAUTIONS 6 4 GETTING TO KN...

Page 2: ...BOVE NEVER USE THIS APPLIANCE FOR HEATING ROOMS NEVER USE PACKAGING RESIDUES UNATTENDED IN THE HOME SEPARATE THE VARIOUS WASTE PACKAGING MATERIALS BY TYPE AND CONSIGN THEM TO THE NEAREST SEPARATE DISP...

Page 3: ...for the addresses of collection recycling and disposal facilities Never leave all or part of the packaging lying around Packaging parts and especially plastic bags may represent a suffocation hazard...

Page 4: ...ECT THE PLUG BY PULLING ON THE POWER SUPPLY LEAD THE APPLIANCE MUST BE CONNECTED TO EARTH IN COMPLIANCE WITH ELECTRICAL SYSTEM SAFETY REGULATIONS IMMEDIATELY AFTER INSTALLATION CARRY OUT A QUICK TEST...

Page 5: ...type and consign them to the nearest separate disposal centre The inside of the appliance should be cleaned to remove all manufacturing residues For further information see point 6 USING THE HOB When...

Page 6: ...until the burner lights If it does not light within the first 15 seconds turn the knob to 0 and wait at least 60 seconds before trying to light the burner again On models equipped with valves once th...

Page 7: ...gh to prevent the liquid from boiling over When cooking to prevent burns or damage to the hob all pans or griddle plates must be placed inside the perimeter of the hob Take the greatest care when usin...

Page 8: ...2 Food stains or spills Never use metal scouring pads or sharp scrapers which will damage the surface Use ordinary non abrasive products for steel with the aid of wooden or plastic utensils if necessa...

Page 9: ...e work surface observing a minimum distance of 50 mm from the rear edge The lower part of the protective cover must be fully accessible when the appliance is installed This appliance can be installed...

Page 10: ...e supporting structure do not use mechanical or electric screwdrivers and apply only moderate pressure to the fixing components by hand Important when fixing the product always use the brackets provid...

Page 11: ...e less than 600 mm above the highest part of the hob shall be protected for the full width and depth of the cooking surface area in accordance with Clause 5 12 1 2 However in no case shall this cleara...

Page 12: ...accordance with current regulations For proper operation of a gas appliance it is essential for the air necessary for combustion of the gas to be able to flow naturally into the room Air must flow di...

Page 13: ...on to allow the gas to be turned off and disconnected for servicing and removal of the appliance as required from the gas supply Before the appliance is operated make certain all relevant parts are pl...

Page 14: ...least 3 mm located in an easily accessible position close to the appliance itself If a socket and plug connection is used check that they are of the same type Do not use reducers adapters or junction...

Page 15: ...types of gas the burner nozzles have to be changed and the gas taps adjusted to set the minimum flame To replace the nozzles proceed as described below 10 1 Changing the hob nozzles 1 Remove the pan...

Page 16: ...or mm Auxiliary 1 3 9 0 54 Semi rapid 2 6 3 0 68 Rapid 3 10 8 0 85 Ultra rapid 4 15 0 1 05 Burner NG 1 0 kPa Nominal gas Consumption MJ h Injector mm Auxiliary 1 3 9 0 90 Semi rapid 2 7 5 1 20 Rapid 3...

Page 17: ...screw inside or beside the tap rod depending on the model until an even minimum flame is obtained Put the knob back in place and check the stability of the burner flame the flame must not go out when...

Page 18: ......

Page 19: ......

Page 20: ...914772987 B...

Reviews: