Installation
72
Connection with a steel hose with conical
fitting
Make the connection to the gas mains
using a continuous wall steel hose whose
specifications comply with the applicable
standard.
Carefully screw the hose connector
3
to the
appliance’s gas connector
1
(½” thread
ISO 228-1), placing the supplied seal
2
between them. Apply insulating material to
the thread of connector
3
, then tighten the
steel hose
4
to the connector
3
.
Connection to LPG
Use a pressure regulator and make the
connection on the gas cylinder, following
all applicable standards and regulations.
The supply pressure must comply with the
values indicated in the table in “Burner and
nozzle characteristics tables”.
Room ventilation
The appliance should be installed in rooms
that have a permanent air supply in
accordance with the standards in force. The
room where the appliance is installed must
have enough air flow for the regular
combustion of gas and the necessary air
change in the room itself. The air vents,
protected by grilles, must be the right size to
comply with current regulations and
positioned so that no part of them is
obstructed, not even partially.
The room must be kept adequately
ventilated in order to eliminate the heat and
humidity produced by cooking: In
particular, after prolonged use, you are
recommended to open a window or to
increase the speed of any fans.