Instructions for the installer

 

 

3.

 

ELECTRICAL CONNECTION 

 

 

Make sure that the voltage and capacity of the power line conform to the 
data shown on the plate located under the casing. 

Do not remove this 

plate for any reason.

 

 

 

The plug on the end of the supply cable and the wall socket must be the 
same type and conform to the current electrical system regulations. 
Check that the power line is adequately grounded. 

 

 

On the power line, install an omnipolar cut-off device with contact cut-off 
distance greater than or equal to 

3 mm

, located in an easily accessible 

position near the unit. 

 

 

Do not use reducers, adapters or shunts. 

 
 

 

 

 

 

If the power cable is replaced, the wire section on the new cable must 
not be less than 1.5 mm

2

 (3 x 1.5 cable), keeping in mind that the end to 

be connected to the hob must have the ground wire (yellow-green) 
longer by at least 20 mm. Use only H05V2V2-F cable or similar which has 
a maximum temperature of 90°C. Any replacement needed should be 
carried out by a specialised technician who should make the mains 
connections according to the following diagram. 

 

L

 = brown 

N

 = blue 

= yellow-green

 

 

 

 

 

 

 

 

 

The manufacturer will not be liable

 

for any damage to persons or 

property caused by non-observance of the above instructions or deriving 
from the tampering of even a single part of the hob. 

 

 

 

 

26

 

Summary of Contents for SLRV596X1

Page 1: ..._______________________________________ 34 8 CLEANING AND MAINTENANCE ___________________________ 37 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON THE...

Page 2: ...DECLINES ALL RESPONSIBILITY FOR IMPROPER USE DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE IT IS...

Page 3: ...LE PLATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB THE HOB IS TO BE USED BY ADULTS ONLY DO NOT LET UNSUPERVISED CHILDREN PLAY WITH THE HOB THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEA...

Page 4: ...nted against walls higher than the work surface on condition that a certain distance X be kept between the appliance and the wall as shown in the figure so as to avoid damage from overheating Make sur...

Page 5: ...a hollow compartment with doors a separating panel has to be placed under the hob Keep a minimum distance of 10 mm between the bottom of the unit and the panel surface The panel has to be easily remov...

Page 6: ...cessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must not be less than 1 5 mm 2 3 x 1 5 cable keeping in mind tha...

Page 7: ...n inspected for G25 2L 3B P at a pressure of 25 mbar For use with other types of gases see Section 5 ADAPTATION TO DIFFERENT TYPES OF GAS The gas intake fitting is gas external threaded ISO 228 1 Conn...

Page 8: ...takes protected by screens must be appropriately sized regulations in force and placed so as not to be blocked in any way The room where the oven is installed should be suitably ventilated to avoid ov...

Page 9: ...ced and the primary air adjusted To replace the nozzles and regulate the burners you have to remove the top as described in the following paragraph 5 1 Removing the hob 1 Remove all the knobs the grid...

Page 10: ...icated in the chart in paragraph 5 4 Regulation of primary air and then secure the tube by means of screw A After the regulations have been carried out restore the seals with sealing wax or equivalent...

Page 11: ...t restore the seals with sealing wax or equivalent material Burner Rated heating capacity kW G25 25 mbar Nozzle diameter 1 100 mm Reduced flowrate W Auxiliary 1 1 05 76 380 Semi rapid 2 1 65 98 380 Ra...

Page 12: ...model until you get a suitable minimum flame Replace the knob and check burner flame stability rapidly turning the knob from maximum to minimum position the flame should not go out 6 2 Regulation of m...

Page 13: ...uxiliary 2 Semi rapid 3 Rapid 4 Ultra rapid 5 Double crown 6 Fish pan 7 Ultra rapid 6 4 Lubrication of gas taps After a while the gas tap may become hard to turn or lock If this happens it has to be c...

Page 14: ...ng one corresponding to the small inner burner and a short one to the outer burner Double crown burners comprise an auxiliary and a rapid burner controlled by two different knobs which permit to use b...

Page 15: ...ence numbers see page 33 7 4 Using a griddle plate A few precautions are necessary if you wish to use a griddle plate leave a gap of at least 160 mm between the edge of the griddle plate and the side...

Page 16: ...h boiling point to roast delicate meat or fish 5 Strong For roasts steaks and large boiled joints 3 6 Very strong To boil large amounts of water to fry WARNING When switching on the electric element f...

Page 17: ...e surface always use specific products only which do not contain abrasive substances or chlorine based acid substances How to use pour the product on a damp cloth and wipe the surface rinse thoroughly...

Page 18: ...roducts for appliance cleaning and care 8 2 1 Ignition plugs and safety devices For good functioning of the lighting ignition plugs and the safety devices keep them very clean Check frequently and cle...

Reviews: