![Smeg SI1F7955B User Manual Download Page 11](http://html1.mh-extra.com/html/smeg/si1f7955b/si1f7955b_user-manual_1302704011.webp)
connected to a single phase exceeds
3700 W.
• The function decreases the power to
the other cooking zones connected to
the same phase.
• The heat setting display of the reduced
zones changes between two levels.
Auto-Vent
It is an advanced automatic function which
connects the hob to an Auto-Vent hood.
Both the hob and the hood have an
infrared signal communicator. Speed of
the fan is defined automatically on basis of
mode setting and temperature of the
hottest cookware on the hob. You can
also operate the fan from the hob
manually.
For most of the hoods the
remote system is originally
deactivated. Activate it before
you use the function. For more
information refer to hood user
manual.
Operating the function automatically
To operate the function automatically set
the automatic mode to H1 – H6. The hob
is originally set to H5. The hood reacts
whenever you operate the hob. The hob
recognizes temperature of the cookware
automatically and adjusts the speed of the
fan.
Automatic modes
Auto‐
matic
light
Boil‐
ing
1)
Fry‐
ing
2)
Mode
H0
Off
Off
Off
Mode
H1
On
Off
Off
Mode
H2
3)
On
Fan
speed
1
Fan
speed
1
Mode
H3
On
Off
Fan
speed
1
Mode
H4
On
Fan
speed
1
Fan
speed
1
Mode
H5
On
Fan
speed
1
Fan
speed
2
Mode
H6
On
Fan
speed
2
Fan
speed
3
1) The hob detects the boiling process and activates
fan speed in accordance with automatic mode.
2) The hob detects the frying process and activates
fan speed in accordance with automatic mode.
3) This mode activates the fan and the light and does
not rely on the temperature.
Changing the automatic mode
1. Deactivate the appliance.
2. Touch for 3 seconds. The display
comes on and goes off.
3. Touch
for 3 seconds.
4. Touch
a few times until
comes on.
5. Touch of the Timer to select an
automatic mode.
To operate the hood directly on
the hood panel deactivate the
automatic mode of the function.
11