EN
9
9
USE
L
L1
T1
T2
T3
T4
L2
L3
L4
Control panel
Button Function
Led
L
Turns the lighting system on and off.
-
Press and hold for approx. 2 seconds to turn the
lighting system on and off at reduced intensity.
-
T1
Turn the suction motor on and off at speed one.
On.
Press and hold the button for approximately 2
seconds, with all the loads turned off (Motor and
Lights), to reset the Filters and turn off the Leds
that are lit.
After 100 working hours all the LEDs
(L1-L2-L3-L4) will light up and
remain lit to indicate saturation of the
metal grease filters.
After 200 working hours all the LEDs
(L1-L2-L3-L4) will light up and start
to flash to indicate saturation of the
activated charcoal filters.
T2
Turn the suction motor on at speed two.
On.
Press and hold for approximately 5 seconds, with
all the loads turned off (Motor and Lights), to
enable/disable the Remote control.
2 flashes, Remote control Enabled.
1 flash, Remote control Disabled.
T3
Turn the suction motor on at speed three.
On.
Press and hold the button for 2 seconds to activate
intensive speed. This speed is timed to run for 10
minutes. At the end of this time the system will
automatically return to the speed set before.
T4
Press and hold the button for approximately 2
seconds to activate automatic shutdown with a 30'
delay (Motor+Lights).
On.
Press and hold for approximately 5 seconds to
enable/disable the Activated Charcoal Filter alarm.
2 Flashes of the Leds (L1-L2-L3)
Filter Alarm Enabled.
1 Flash of the Leds (L1-L2-L3) Filter
Alarm Disabled.
Summary of Contents for SHW410X
Page 1: ...Instructions Manual SHW410X ...
Page 12: ...436006018_ver2 ...