Recommendations and suggestions

• 

The Instructions for Use apply to several versions of 

this appliance. Accordingly, you may find descriptions 

of individual features that do not apply to your specific 

appliance.

• 

The manufacturer will not be held liable for any 

damages resulting from incorrect or improper 

installation.

• 

The minimum safety distance between the cooker 

top and the extractor hood is 650 mm (some models 

can be installed at a lower height, please refer to the 

paragraphs on working dimensions and installation).

• 

Check that the mains voltage corresponds to that 

indicated on the rating plate fixed to the inside of the 

hood.

• 

For Class I appliances, check that the domestic power 

supply guarantees adequate earthing.

•  Connect the extractor to the exhaust flue through a pipe 

of minimum diameter 120 mm. The route of the flue 

must be as short as possible.

• 

Do not connect the extractor hood to exhaust ducts 

carrying combustion fumes (boilers, fireplaces, etc.).

• 

If the extractor is used in conjunction with non-electrical 

appliances (e.g. gas burning appliances), a sufficient 

degree of aeration must be guaranteed in the room 

in order to prevent the backflow of exhaust gas. The 

kitchen must have an opening communicating directly 

with the open air in order to guarantee the entry of clean 

air. When the cooker hood is used in conjunction with 

appliances supplied with energy other than electric, the 

negative pressure in the room must not exceed 0,04 

mbar to prevent fumes being drawn back into the room 

by the cooker hood.

• 

In the event of damage to the power cable, it must be 

replaced by the manufacturer or by the technical service 

department, in order to prevent any risks.

• 

If the supply cord is damaged, it must be replaced from 

the manufacturer or its service agent.

• 

Connect the hood to the mains through a two-pole 

switch having a contact gap of at least 3 mm.

Use

• 

The extractor hood has been designed exclusively for 

domestic use to eliminate kitchen smells.

• 

Never use the hood for purposes other than for which it 

has been designed.

•  Never leave high naked flames under the hood when it 

is in operation.

•  Adjust the flame intensity to direct it onto the bottom 

of the pan only, making sure that it does not engulf the 

sides.

• 

Deep fat fryers must be continuously monitored during 

use: overheated oil can burst into flames.

•  Do not flambè under the range hood; risk of fire.

• 

This appliance is not intended for use by persons 

(including children) with reduced physical, sensory 

or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision or 

instruction concerning use of the appliance by a person 

responsible for their safety.

• 

Children should be supervised to ensure that they do 

not play with the appliance. 

• 

“ CAUTION: Accessible parts may become hot when 

used with cooking appliances”.

Maintenance

• 

The symbol   on the product or on its packaging 

indicates that this product may not be treated as 

household waste. Instead it shall be handed over 

to the applicable collection point for the recycling of 

electrical and electronic equipment. By ensuring this 

product is disposed of correctly, you will help prevent 

potential negative consequences for the environment 

and human health, which could otherwise be caused by 

inappropriate waste handling of this product. For more 

detailed information about recycling of this product, 

please contact your local city office, your household 

waste disposal service or the shop where you 

purchased the product.

• 

Switch off or unplug the appliance from the mains 

supply before carrying out any maintenance work.

•  Clean and/or replace the Filters after the specified time 

period (Fire hazard).

 -

Activated charcoal filter 

W

 These filters are not 

washable and cannot be regenerated, and must be 

replaced approximately every 4 months of operation, 

or more frequently with heavy usage.

W

EN

Summary of Contents for SHU501X

Page 1: ...User Manual SHU501X SHU701X ...

Page 2: ...EN USER MANUAL 3 ...

Page 3: ... switch having a contact gap of at least 3 mm Use The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has been designed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the s...

Page 4: ...Motor on at Speed one Turns the Motor off T2 Speed On Turns the Motor on at Speed two T3 Speed Fixed When pressed briefly turns the Motor on at Speed three Flashing Pressed for 2 Seconds Activates Speed four with a timer set to 10 minutes after which it returns to the speed that was set previously Suitable to deal with maximum levels of cooking fumes L Light Turns the Lighting System on and off Wa...

Page 5: ...a di procedere all instal lazione leggere le Avvertenze e Suggeri menti contenute nel Libretto di Uso FI Varoitus Ennen kuin aloitat asennuksen lue käyttöohjeen sisältämät turvallisuuso hjeet DA Vigtigt Læs brugsanvisningens instruk tioner vedrørende sikkerhed før instal lationen påbegyndes sigurnosne informacije u Uputama za uporabu PT Atenção Antes de continuar a instalação leia as informações d...

Page 6: ...L 8x A 520mm L 10x A 700mm 3 ...

Page 7: ...1x ø 120 mm ø 150 mm 1x ø 150 mm FP FP 4 ...

Page 8: ...1 5 ...

Page 9: ...2 3 6 ...

Page 10: ...5 4 A 520 700 L1 497 677 L 7 ...

Page 11: ... 6 7 8 ...

Page 12: ...8 9 W Z 9 ...

Page 13: ... 10 10 ...

Page 14: ......

Page 15: ...991 0318 955_02 140224 ...

Reviews: