Disconnect the appliance from the mains supply
prior to any conversions being carried out.

7) CHANGING THE TYPE OF POWER
SUPPLY

Although they leave our factory preset for single-
phase connection, certain appliances may by
converted to the threephase system.
Comply with the following instructions:
a) Remove the hotplate from the top of the cabinet,
overturn it, unscrew screw "Z" and remove under
part (see fig. 9).

b)  Shift connecting plate on terminal according to
the following chart. This chart is also affixed to the
hob.
c) Insert a supply cable of adequate section (see
chart par. 10) through core hitch on the terminal
board.
d) Connect the phase and earth wires to the relative
terminal board.
e) Fix the supply cable in place using clamp.
f) Refit the hotplate, complying with the above
instructions in reverse.

FIG. 9

FIG. 10

Summary of Contents for SE435XT

Page 1: ...correct installation or use of the appliance The Manufacturer shall not be held responsible for any inaccuracies in this handbook due to printing or transcription errors the designs in the figures are...

Page 2: ...f 1000 W 2 Normal plate 180 of 1500 W 7 Control knob for electric plate n 1 8 Control knob for electric plate n 2 13 Warning light indicating that one or more plates are operating DESCRIPTION OF THE H...

Page 3: ...ing light will come on to indicate that the plate has been ignited 2 HOW TO USE THE ELECTRIC PLATES A purely indicative plate regulation chart is given below FIG 1 FIG 2 0 Off 1 1 Weak 2 1 4 Low 3 4 8...

Page 4: ...pecial products easily available on the market This will keep the surface of the plate clean and bright The operation will also prevent the formation of rust Never allow children to play near the appl...

Page 5: ...are still warm and never use abrasive powders Do not allow vinegar coffee milk salted water lemon or tomato juice from remaining in contact with the enamelled surfaces for long periods of time WARNIN...

Page 6: ...5 FIXING THE HOT PLATE The hob has a special seal which prevents liquids from infiltrating into the cabinet Strictly comply with the following instructions in order to correctly apply this seal Detac...

Page 7: ...e Letter N neutral blue wire Earth symbol yellow green wire The powering cable must be positioned so that it is never able to reach an overtemperature of 75 K in any part Never use reductions adapters...

Page 8: ...emove the hotplate from the top of the cabinet overturn it unscrew screw Z and remove under part see fig 9 b Shift connecting plate on terminal according to the following chart This chart is also affi...

Page 9: ...or longer than live ones and must respect the cautions in paragraph Electrical connection To reassemble the appliance repeat the inverse process 9 TECHNICAL CHARACTERISTICS OF THE ELECTRICAL COMPONENT...

Page 10: ...VOLTAGE 110 V FREQUENCY 50 60 Hz TOT RATING 5000 W MODEL WITH 4 NORMAL PLATES 10 TECHNICAL DATA...

Page 11: ...e model of appliance in your possession Please also note that genuine spare parts are only available from our After Sales Service Centres and authorized retail outlets The above data are printed on th...

Page 12: ...12...

Reviews: