6) ELECTRICAL CONNECTIONS

Electrical connection must be carried out in
compliance with the specifications and
provisions in force.
Before proceeding with the connections, check that:
- the voltage rating of the appliance and the

current sockets suits the maximum power draw
of the appliance (see data label affixed to the
lower part of the appliance itself).

- The system is equipped with an efficient earth

connection in compliance with the pertinent
provisions in force. The manufacturer declines all
responsibility for failure to comply with these
provisions.

- If the appliance has no power cable, connect a

cable of adeguate section to the terminal strip
(consult the table on next page) complying with
the wiring diagram of fig. 7. This diagram is also
affixed to the hot plate.

When connection to the electricity main is made
by using a socket (gas version only):
- fit a standard plug to power cable (if supplyied).

This plug should be able to bear the load
indicated on the data label. Connect the wires
according to the diagram in fig. 7, remembering
to comply with the following instructions:

letter L (live) = brown wire;
letter N (neutral) = blue wire;
earth symbol  

1

= yellow-green wire.

- The powering cable must be positioned so that it

is never able to reach an overtemperature of 65K
in any part.

- Never use reductions, adapters or shunts for the

connection since these could cause false
contacts and dangerous overheating.

- The outlet must be accessible after the built-in.

When the appliance is connected straight to the
electricity main:
- install an omnipolar cutout between the

appliance itself and the main. This circuit-breaker
should be sized according to the rating of the
appliance and the opening between its contacts
should be at least 3 mm.

- Remember that the earth wire must not be cutout

by the switch.

- Alternatively, the electrical connection may also

be protected by a high sensitivity differential
switch.

Installers are strongly advised to connect the
yellow-green earthing wire to an efficient earthing
system.
The manufacturer cannot be responsible for the
missing earthing of the appliance.

WARNINGS:
all our appliances are designed and
manufactured in compliance with European
standards EN 60 335-1 and EN 60 335-2-6 plus
the relative amendments.
The appliance complies with the provisions of
the following EEC Directives: 
- CEE 89/336 + 92/31 + 93/68 regarding to

electromagnetic compatibility.

- CEE 73/23 + 93/68 regarding electrical safety.

FIG. 7

Summary of Contents for SE32X

Page 1: ...incorrect installation or use of the appliance The Manufacturer shall not be held responsible for any inaccuracies in this handbook due to printing or transcription errors the designs in the figures a...

Page 2: ...1500 W 5 Plate 180 of 1500 2000 W 11 Control knob for electric plate n 4 12 Control knob for electric plate n 5 13 Warning light indicating that one or more plates are operating DESCRIPTION OF THE HO...

Page 3: ...the knob in question corresponds see fig 1 A red warning light will come on to indicate that the plate has been ignited 2 HOW TO USE THE ELECTRIC PLATES A purely indicative plate regulation chart is...

Page 4: ...pecial products easily available on the market This will keep the surface of the plate clean and bright The operation will also prevent the formation of rust Never allow children to play near the appl...

Page 5: ...are still warm and never use abrasive powders Do not allow vinegar coffee milk salted water lemon or tomato juice from remaining in contact with the enamelled surfaces for long periods of time WARNIN...

Page 6: ...has a special seal which prevents liquids from infiltrating into the cabinet Strictly comply with the following instructions in order to correctly apply this seal detach the seals from their backing...

Page 7: ...tter N neutral blue wire earth symbol 1 yellow green wire The powering cable must be positioned so that it is never able to reach an overtemperature of 65K in any part Never use reductions adapters or...

Page 8: ...spect the cautions in paragraph Electrical connection To reassemble the appliance repeat the inverse process 8 TECHNICAL CHARACTERISTICS OF THE ELECTRICAL COMPONENTS To facilitate the job of the insta...

Page 9: ...VOLTAGE 230 240 V FREQUENCY 50 60 Hz TOT RATING 2500 W MODEL WITH 2 NORMAL PLATES 9 TECHNICAL DATA VOLTAGE 230 240 V FREQUENCY 50 60 Hz TOT RATING 3500 W MODEL WITH 2 RAPID PLATES...