Installation
38
When the job is complete, the installer must
issue a certificate of conformity.
1
Extraction using a hood
2
Extraction without a hood
A
Single natural draught chimney
B
Single chimney with extractor fan
C
Directly outdoors with wall- or window-
mounted extractor fan
D
Directly outdoors through wall
Air
Combustion products
Extractor fan
5.2 Adaptation to different types of
gas
In case of operation with other types of gas,
the burner nozzles must be changed and
the minimum flame adjusted on the gas
taps.
Replacing nozzles
1. Remove the grids, burner caps and
flame-spreader crowns in order to
access the burner cups.
2. Replace the nozzles using a 7 mm socket
wrench according to the gas to be used
(see "Nozzle and burner specification
tables").
3. Reposition the burners in their respective
housings.
Adjusting the minimum setting for natural
or town gas
Light the burner and turn it to the minimum
position. Remove the gas tap knob and turn
the adjustment screw next to the tap rod
(depending on the model) until the correct
minimum flame is obtained.
The appliance is preset for natural
gas
G20
at a pressure of
20 mbar
.