33
Instructions for the installer
Operation at 220-240 V~:
use a
H05RR-F / H05RN-F three-wire cable
(cable of 3 x 4 mm
2
).
Operation at 380-415V2N~
: use a type
H05RR-F / H05RN-F four-wire cable
(cable of 4 x 2.5 mm
2
).
Operation at 380-415V3N~
: use a type
H05RR-F / H05RN-F five-wire cable
(cable of 5 x 1.5 mm
2
).
The earth wire (yellow-green) must be at
least 20 mm longer than the other wires
at the end for connection to the
appliance.
14.2 Positioning the oven
The appliance is designed for building-in to cabinets made from any heat-
resistant material. Comply with the dimensions shown in figures
1
,
2
,
and
3
. When installing under worktops, comply with the dimensions shown in
figure
1
-
3
. When installing under worktops incorporating combined hobs, a
gap of at least 110 mm must be left from any side wall, as shown in figure
1
. When installing in tall units, comply with the dimensions shown in figure
1
-
2
, bearing in mind that the top/rear of the unit must have an opening 80-
90 mm deep. Screw the 4 screws
A
into the inside of the frame (fig.
1
). For
installation under counter-top hobs, make sure that the rear/bottom of the
unit has an opening similar to that shown in figure
1
(ref.
B
). See the
instructions supplied with the hob for the relative positioning and fixing
procedures.