![Smeg RCD50XZA Manual Download Page 13](http://html1.mh-extra.com/html/smeg/rcd50xza/rcd50xza_manual_1304030013.webp)
PAGE 10
Control buttons
REFRIGERATOR TEMPERATURE
MODE SELECTION
LOCK / UNLOCK BUTTON
FREEZER TEMPERATURE
A
B
C
D
0peration instructions
1)
Display
• When you turn on the power to the refrigerator, the display screen will total display for 3 seconds. Meanwhile the
starting up bell rings and then the screen enters the normal display of the operation.
• The first time for using the refrigerator, the default set temperature of refrigerating chamber and freezing chamber is
5° C/-18 ‘ C respectively.
• When an error occurs, the display shows the error code (see next page); during normal running, the display shows
the set temperature of the refrigerating chamber or freezing chamber.
• Under normal circumstances, if there is no operation on display panel or door opening action
within 30s, then the display is locked, and the state 6 goes out.
2)
Lock /unlock
• In the unlocked state, long press the lock button
D
for 3 seconds, enter the lock state, The logo
6
goes out and buzzer
sounds, it means the display panel is locked, at this time, button operation cannot be implemented; In the locked state,
long press the lock button
D
for 3 seconds , enter the unlocked state , The logo
6
lights up and buzzer sounds, it
means the display panel is unlocked, at this time, button operation can be Implemented.
3)
Temperature setting of refrigerating compartments.
• Press temperature adjusting button of the refrigerating compartment A to change the setting temperature of
refrigerating chamber, and then each time a press of temperature adjusting button of the refrigerating compartment,
the temperature will be reduced 1° C.
• The temperature setting range for refrigerating chamber is 2-8° C.
• When the temperature is 2° C, press the button again, and the temperature of refrigerating chamber will be set at
8° C, and it circulates accordingly.
4)
Temperature setting of freezing compartments
• Press temperature adjusting button of the freezing compartments B to change the setting temperature of freezing
compartment and then each time a press of temperature adjusting button of the freezing compartment the temperature
will be reduced1’t;
• The temperature setting range for freezing compartment is -24°C~-16°C).
When the temperature is -24°C, press the button again, and the temperature of freezing chamber will be set at
-16°C, and it circulates accordingly.