Installation
64
The nozzles not provided are available at Authorised Service Centres.
8
Natural gas G2.350 – 13 mbar
AUX
SR
RR
UR*
UR2 int.
UR2 ext.
Rated heating capacity (kW)
-
-
-
-
-
-
Nozzle diameter (1/100 mm)
-
-
-
-
-
-
Reduced flow rate (W)
-
-
-
-
-
-
Primary air (mm)
-
-
-
-
-
-
9
LPG G30/31 - 30/37 mbar
AUX
SR
RR
UR*
UR2 int.
UR2 ext.
Rated heating capacity (kW)
1.10
1.8
2.6
4.0
1.1
3.1
Nozzle diameter (1/100 mm)
48
62
76
95
48
85
Reduced flow rate (W)
400
500
750
1800
400
1400
Primary air (mm)
1.5
1.5
1.5
10
1.5
10
Rated flow rate G30 (g/h)
76
182
189
291
76
225
Rated flow rate G31 (g/h)
75
179
186
286
75
221
10
LPG G30/31 - 37 mbar
AUX
SR
RR
UR*
UR2 int.
UR2 ext.
Rated heating capacity (kW)
-
-
-
-
-
-
Nozzle diameter (1/100 mm)
-
-
-
-
-
-
Reduced flow rate (W)
-
-
-
-
-
-
Primary air (mm)
-
-
-
-
-
-
Rated flow rate G30 (g/h)
-
-
-
-
-
-
Rated flow rate G31 (g/h)
-
-
-
-
-
-
11
LPG G30/31 - 50 mbar
AUX
SR
RR
UR*
UR2 int.
UR2 ext.
Rated heating capacity (kW)
-
-
-
-
-
-
Nozzle diameter (1/100 mm)
-
-
-
-
-
-
Reduced flow rate (W)
-
-
-
-
-
-
Primary air (mm)
-
-
-
-
-
-
Rated flow rate G30 (g/h)
-
-
-
-
-
-
Rated flow rate G31 (g/h)
-
-
-
-
-
-
12
Town gas G110 – 8 mbar
AUX
SR
RR
UR*
UR2 int.
UR2 ext.
Rated heating capacity (kW)
1.10
1.8
2.6
4.0
1.1
3.1
Nozzle diameter (1/100 mm)
132
165
210
290
132
240
Reduced flow rate (W)
400
500
750
1400
400
1400
Primary air (mm)
0.5
1
0.5
1.5
1
1
13
Town gas G120 – 8 mbar
AUX
SR
RR
UR*
UR2 int.
UR2 ext.
Rated heating capacity (kW)
-
-
-
-
-
-
Nozzle diameter (1/100 mm)
-
-
-
-
-
-
Reduced flow rate (W)
-
-
-
-
-
-
Primary air (mm)
-
-
-
-
-
-