Installation
60
The nozzles not provided are available at Authorised Service Centres.
8
LPG G30/31 - 30/37 mbar
AUX
SR
RR
R
UR
UR*
Rated heating capacity (kW)
1.1
1.7
2.6
3.1
4.2
6.0
Nozzle diameter (1/100 mm)
48
62
76
85
98
115
Reduced flow rate (W)
400
500
750
1100
1600
1800
Primary air (mm)
1.5
2
2
8
10
12
Rated flow rate G30 (g/h)
80
124
189
225
305
436
Rated flow rate G31 (g/h)
79
121
186
221
300
429
9
LPG G30/G31 - 37 mbar
AUX
SR
RR
R
UR
UR*
Rated heating capacity (kW)
1.1
1.7
2.6
3.1
4.2
6.0
Nozzle diameter (1/100 mm)
48
60
73
80
93
110
Reduced flow rate (W)
450
550
850
1100
1600
1800
Primary air (mm)
1.5
2
1.5
10
10
12
Rated flow rate G30 (g/h)
80
124
189
225
305
436
Rated flow rate G31 (g/h)
79
121
186
221
300
429
10
LPG G30/G31 - 50 mbar
AUX
SR
RR
R
UR
UR*
Rated heating capacity (kW)
1.1
1.7
2.7
3.1
4.2
6.0
Nozzle diameter (1/100 mm)
42
54
67
76
85
102
Reduced flow rate (W)
450
550
850
1100
1600
1800
Primary air (mm)
1
1
0.5
2
2
2.5
Rated flow rate G30 (g/h)
80
124
196
225
305
436
Rated flow rate G31 (g/h)
79
121
193
221
300
429
11
Town gas G110 – 8 mbar
AUX
SR
RR
R
UR
UR*
Rated heating capacity (kW)
1.1
1.7
2.6
3.1
3.8
3.8
Nozzle diameter (1/100 mm)
132
165
230
250
310
310
Reduced flow rate (W)
400
500
750
900
1400
1400
Primary air (mm)
1
0.5
1
1
1.5
1.5
12
Town gas G120 – 8 mbar
AUX
SR
RR
R
UR
UR*
Rated heating capacity (kW)
1.1
1.7
2.6
3.1
4.0
4.0
Nozzle diameter (1/100 mm)
126
160
210
230
310
310
Reduced flow rate (W)
400
500
750
900
1400
1400
Primary air (mm)
1
0.5
1
1
1.5
1.5