Installation
19
EN
Hob seal
To prevent leakage of liquid between the
frame of the hob and the work surface,
place the adhesive seal provided along the
entire outer edge of the hob before
assembly.
5.5 Fixing brackets
Screw the fixing brackets (
A
) into the holes
on the sides of the bottom casing to
properly fasten the hob to the structure.
Room ventilation
The room containing the appliance should
have a permanent air supply in accordance
with the standards in force. The room where
the appliance is installed must have enough
air flow needed for the regular combustion
of gas and the necessary air change in the
room itself. The hob shall be installed in
rooms with natural ventilation, as required
by Standards regulations AS/NZS5601.
Combustion gas discharge
Combustion gases may be discharged by
means of hoods connected to a flue with
reliable natural draught, or a fan extraction
system. An effective extraction system
requires careful design by an authorised
specialist, and must comply with the
regulation distances and positions. After
installation, the engineer must issue a
certificate of compliance.
Do not use silicone to secure the
hob. This would make it impossible
to remove the hob, if necessary,
without damaging it.