Smeg PU64ES Manual Download Page 12

Instructions for the Installer

14

5. CHECKING OPERATION

After having fastened the top to the support structure, some simple procedures are required to check for
proper operation.

1)

Check for any gas leaks in the vicinity of the cooktop connector, the pressure regulator and the safety
valve.

  WARNING

FIRE HAZARD

-  Use a soapy solution to check for proper tightness.

-  Never test for gas leaks with a match or other flames.

-  Failure to follow this instruction can result in death or fire

NOTE: 

 The regulator Is fitted with a checkpoint outlet gas pressure to check the exact pressure supplied

to the appliance.

2)

Refit the crowns, flame caps and grids on the cooktop in the
following order:

1 Fit the crowns, ensuring that they are perfectly locked into their

housing on the cooktop.

2 Fit the flame caps on the crowns, ensuring that the edges

match perfectly.

3 Fit the grids, making sure to fasten the side spokes in the

special “

A

” seats found on the cooktop.

These procedures must be repeated for each burner on the
cooktop.

CAUTION: refit all flame caps in the same points from which they were removed. In fact, the flame
cap positions cannot be changed. After refitting them, ensure that they are fitted perfectly and
that there is no clearance between the top and the flame caps.

3)

The cooktop's electrical circuit can be checked for proper operation
only after top assembly has been completed as described in step
2) and you have checked to ensure that all parts have been fitted
properly:

1 a spark must light on all burners when the knobs on the top are

pressed

2 when each knob on the cooktop is pressed and turned to the

min flame symbol (   ), the entire crown should light.

3 lf burners do not light properly, turn the control knob to the

"OFF" position   . Check that burner caps and crowns are in
the proper position. Check that the power supply cord is
plugged in and that circuit breaker or house fuse has not blown.
Check that the shut-off valve is in the "ON" position. Check
operation again. lf a burner does not light at this point, contact
your dealer for assistance.

Summary of Contents for PU64ES

Page 1: ...OP AND LOCATION REQUIREMENTS 6 3 1 Gas supply requirements 8 3 2 Electrical requirements 9 4 INSTALLING THE COOKTOP 11 5 CHECKING OPERATION 14 6 WIRING DIAGRAMS 15 INSTRUCTIONS FOR THE INSTALLER these...

Page 2: ...ernment codes and ordinances WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death Do...

Page 3: ...Instructions for the Installer 5 2 COOKTOP MEASUREMENTS...

Page 4: ...ws air downward toward the appliance unless the ventilation system and appliance have been designed tested in accordance with ANSI Z21 1 and listed by an independent testing laboratory for combination...

Page 5: ...1 8 483 485 mm 8 1 4 210 mm 3 3 8 86 mm 1 7 16 36 mm 1 3 4 45 mm 27 1 2 700 mm 39 3 8 1000 mm 33 11 16 33 14 16 855 860 mm 19 1 8 19 5 16 485 490 mm 8 1 4 210 mm 4 7 16 112 mm 1 7 16 36 mm 1 3 4 45 mm...

Page 6: ...must conform to American National Standards National Fuel Gas Code ANSI Z223 1 latest edition or CANI 13149 1 or 2 2 If local codes permit a flexible metal appliance connector with the new AGA or CSA...

Page 7: ...tem by closing the respective manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa 6 If the appliance is installed...

Page 8: ...SI NFPA 70 Electrical Code latest edition or the Canadian Electrical Code CSA and local codes and ordinances lf a mating outlet is not available it is the personal responsibility and obligation of the...

Page 9: ...ply pressure for LP operation of the cooktop 1 Unscrew cap A on the pressure regulator 2 Turn it to the part where LP is printed 3 Re tighten it and lock the pins in the slots provided 4 There is an a...

Page 10: ...the hole on the inner side of the gasket The diagram below shows the exact positions of the holes to be used for clamping the hob to the top by the brackets correctly NOTE Use all of the brackets sup...

Page 11: ...s used be certain tubing is not kinked Use only pipes E conforming to standard regulations in force inserting gasket B supplied between fitting A adaptator C The adaptor C must be fitted on the gas co...

Page 12: ...found on the cooktop These procedures must be repeated for each burner on the cooktop CAUTION refit all flame caps in the same points from which they were removed In fact the flame cap positions canno...

Page 13: ...quipped with a threee pronge polarized plug grounding which mates with standard three pronged grounding wall receptacles WARNING Label all wires prior to disconnection when servicing controls Wiring e...

Page 14: ...ith a threee pronge polarized plug grounding which mates with standard three pronged grounding wall receptacles WARNING Label all wires prior to disconnection when servicing controls Wiring errors can...

Page 15: ...ith a threee pronge polarized plug grounding which mates with standard three pronged grounding wall receptacles WARNING Label all wires prior to disconnection when servicing controls Wiring errors can...

Reviews: