 The appliance must be installed by a qualified person 

in compliance with the instructions provided.

!

 Wear gloves when carrying out installation and 

maintenance operations.

AIR VENT

(for ducting versions)

!

  Prepare the hole and the air vent duct (150 mm dia-

meter).

!

  Use a duct of the minimum indispensible length.

!

  Use a duct with as few elbows as possible (maximum 

elbow angle: 90°).

!

  Avoid drastic changes in the duct cross-section.

!

  Use a duct with an as smooth as possible inside.

!

  The duct must be made of certified material.

!

  Do not connect the hood to smoke exhaust ducts 

for the products of combustion (boilers, fireplaces, 

stoves, etc).

!

  For the air vents comply with the provisions laid down 

by the competent authorities.

 

In addition, the air must not be evacuated through a 

hole in the wall unless specifically intended for this 

purpose.

!

  Fit air intakes in the room to prevent the hood from 

creating a negative pressure in the room (which must 

not exceed 0.04 mbar); if the hood is used at the 

same time as non-electrical equipment (gas-, oil- and 

charcoal-fired stoves, etc.) the exhaust gas may be 

sucked in by the heat source.

FILTERING OR DUCTING VERSION ?

The hood may be in filtering or in ducting version.  Deci

-

de from the outset which type is to be installed.

For better efficiency, we recommend installing the hood 

in the ducting version (if possible).

 Ducting version

The hood purifies the air and evacuates it to the outside 

through an exhaust duct (diameter 150 mm).

 Filtering version

The hood purifies the air and recycles  the clean air 

back into the room.

CONTROLS

P1

P2

P3

P4

L

1

P

5

P1:

  5’ TIMER

P2:

  Filter alarm reset  

P3:

  Motor off / speed decrease – .

        - holding down the button, the motor turns off sto-

ring the current speed

P4:

  Motor on / speed  increase

P5:

  Lights on/off  

L1

  Signalling crown: 

Hood in standby:

 lights up amber-orange. 30” after 

the last key has been pressed the crown turns off 

Motor on:

 L1 lights up turquoise flashing. The 

flashing frequency is proportional to the speed 

5’ TIMER function :

 L1 lights up turquoise fixed

Filter alarm active:

 L1 lights up red fixed (30h); L2 

lights up red flashing (120h) 

MAINTENANCE

!

  Before cleaning or maintenance cut the power.

Cleaning the hood

WHEN TO CLEAN IT: clean it at least every 2 months 

to prevent the risk of fire.

EXTERNAL CLEANING: use a cloth moistened in luke-
warm water and neutral detergent (for painted hoods); 

use specific products for steel, copper or brass hoods.

INTERNAL CLEANING: use a cloth (or brush) soaked 

in denatured ethyl alcohol.

WHAT NOT TO DO: do not use abrasive or corrosi-

ve products (e.g. metal sponges, brushes, too hard 

brushes, very aggressive detergents, etc.)

Summary of Contents for POLARB90

Page 1: ...OVER A GAS RANGE OR GAS COOKING HOB A DIFFERENT SPECIFIC MINIMUM HEIGHT REQUIREMENT MAY BE REQUIRED BY THE RELEVANT GAS AUTHORITIES IF THE SUPPLY CORD IS DAMAGED IT MUST BE REPLACED BY THE MANUFACTURER OR ITS SERVICE AGENT OR A SIMILARY QUALIFIED PERSON IN ORDER TO AVOID A HAZARD THE APPLIANCE IS NOT INTENDED FOR USE BY YOUNG CHILDREN OR INFIRM PERSONS WITHOUT SUPERVISION YOUNGCHILDRENSHOULDBESUPE...

Page 2: ... IS DAMAGED IT MUST BE REPLACED BY THE MANUFACTURER OR ITS SERVICE AGENT OR A SIMILARLY QUALIFIED PERSON IN ORDER TO AVOID A HAZARD FOR INSTALLATION INSTRUCTIONS THE EXHAUST AIR MUST NOT BE DISCHARGED INTO A FLUE WHICH IS USED FOR EXHAUSTING FUMES FROM OTHER APPLIANCES BURNING GAS OR OTHER FUELS NOT APPLICABLE FOR APPLIANCES WHICH ONLY DISCHARGE AIR BACK INTO THE ROOM THE MINIMUM DISTANCE BETWEEN ...

Page 3: ...ÅëëçíéêÜ 32 Română 34 Čeština 36 Slovensky 38 Istruzioni per l uso Instructions for use Betriebsanleitung Mode d emploi Instrucciones de uso Instruções de uso Gebruiksaanwijzingen Ðóêîâîäñòâî ïî ýêñïëóàòàöèè Brugsanvisning Käyttöohjeet Bruksanvisning Ïäçãßåò ñÞóçò Instrucţiuni de utilizare Návod k použití Návod na používanie ...

Page 4: ...2 2x 1x ø 15cm 1x 1x ø 12 5cm 1x 1x 1x 1x 1x 8x 8x 4 8x38mm 4x 3 9x6mm 1x 2x 1x 2x 3 9 x 6mm ...

Page 5: ...3 L 65 cm min 1A 1B Ø150mm Ø150mm Ø125 Ø150 Ø125 ...

Page 6: ...4 2 3 4 5 6 55 mm 7 4 8 x 38 mm MIN 1215mm ...

Page 7: ...5 8 10 11 12 13 Ø 8 mm 9 4 8 x 38 mm ...

Page 8: ...6 15 16 18 14 Ø 8 mm 4 8 x 38 mm 19 325 mm 3 9 x 6 mm 17 ...

Page 9: ...7 20A 22A 21A 24A 23A 3 9 x 6 mm 20B ...

Page 10: ...8 25B 23B 3 9 x 6 mm 22B 21B 24B 26B ...

Page 11: ...9 28B 27B 30B 29B 31B 32B ...

Page 12: ...i de from the outset which type is to be installed For better efficiency we recommend installing the hood in the ducting version if possible Ducting version The hood purifies the air and evacuates it to the outside through an exhaust duct diameter 150 mm Filtering version The hood purifies the air and recycles the clean air back into the room CONTROLS P1 P2 P3 P4 L1 P5 P1 5 TIMER P2 Filter alarm r...

Page 13: ... the charcoal filter from its seat Replacing the lamps To change the halogen lamps open the cover levering from the proper slots Replace it with a lamp of the same type WARNING Do not touch the new lamp with bare hands MALFUNCTIONS If something appears not to be working properly do the following simple checks before calling Technical Servi ce If the hood is not working Check that The power has not...

Reviews: