The appliance must be installed by a qualified person
in compliance with the instructions provided.
!
Wear gloves when carrying out installation and
maintenance operations.
AIR VENT
(for ducting versions)
!
Prepare the hole and the air vent duct (150 mm dia-
meter).
!
Use a duct of the minimum indispensible length.
!
Use a duct with as few elbows as possible (maximum
elbow angle: 90°).
!
Avoid drastic changes in the duct cross-section.
!
Use a duct with an as smooth as possible inside.
!
The duct must be made of certified material.
!
Do not connect the hood to smoke exhaust ducts
for the products of combustion (boilers, fireplaces,
stoves, etc).
!
For the air vents comply with the provisions laid down
by the competent authorities.
In addition, the air must not be evacuated through a
hole in the wall unless specifically intended for this
purpose.
!
Fit air intakes in the room to prevent the hood from
creating a negative pressure in the room (which must
not exceed 0.04 mbar); if the hood is used at the
same time as non-electrical equipment (gas-, oil- and
charcoal-fired stoves, etc.) the exhaust gas may be
sucked in by the heat source.
FILTERING OR DUCTING VERSION ?
The hood may be in filtering or in ducting version. Deci
-
de from the outset which type is to be installed.
For better efficiency, we recommend installing the hood
in the ducting version (if possible).
Ducting version
The hood purifies the air and evacuates it to the outside
through an exhaust duct (diameter 150 mm).
Filtering version
The hood purifies the air and recycles the clean air
back into the room.
CONTROLS
P1
P2
P3
P4
L
1
P
5
P1:
5’ TIMER
P2:
Filter alarm reset
P3:
Motor off / speed decrease – .
- holding down the button, the motor turns off sto-
ring the current speed
P4:
Motor on / speed increase
P5:
Lights on/off
L1
Signalling crown:
-
Hood in standby:
lights up amber-orange. 30” after
the last key has been pressed the crown turns off
-
Motor on:
L1 lights up turquoise flashing. The
flashing frequency is proportional to the speed
-
5’ TIMER function :
L1 lights up turquoise fixed
-
Filter alarm active:
L1 lights up red fixed (30h); L2
lights up red flashing (120h)
MAINTENANCE
!
Before cleaning or maintenance cut the power.
Cleaning the hood
WHEN TO CLEAN IT: clean it at least every 2 months
to prevent the risk of fire.
EXTERNAL CLEANING: use a cloth moistened in luke-
warm water and neutral detergent (for painted hoods);
use specific products for steel, copper or brass hoods.
INTERNAL CLEANING: use a cloth (or brush) soaked
in denatured ethyl alcohol.
WHAT NOT TO DO: do not use abrasive or corrosi-
ve products (e.g. metal sponges, brushes, too hard
brushes, very aggressive detergents, etc.)
Summary of Contents for POLARB90
Page 4: ...2 2x 1x ø 15cm 1x 1x ø 12 5cm 1x 1x 1x 1x 1x 8x 8x 4 8x38mm 4x 3 9x6mm 1x 2x 1x 2x 3 9 x 6mm ...
Page 5: ...3 L 65 cm min 1A 1B Ø150mm Ø150mm Ø125 Ø150 Ø125 ...
Page 6: ...4 2 3 4 5 6 55 mm 7 4 8 x 38 mm MIN 1215mm ...
Page 7: ...5 8 10 11 12 13 Ø 8 mm 9 4 8 x 38 mm ...
Page 8: ...6 15 16 18 14 Ø 8 mm 4 8 x 38 mm 19 325 mm 3 9 x 6 mm 17 ...
Page 9: ...7 20A 22A 21A 24A 23A 3 9 x 6 mm 20B ...
Page 10: ...8 25B 23B 3 9 x 6 mm 22B 21B 24B 26B ...
Page 11: ...9 28B 27B 30B 29B 31B 32B ...